REASSEMBL Y PROCEDURE

4. ER·tube

 

 

4. ER·tube

 

4-1.Depression prism unit (Refer to Fig. 11)

1

t.:p

_+_

l)lnsert lenses @ and i@ into mount (D (to be positioned as r;aJ- thicker) and

(";"\

Down t

ftx them with retaining ring\_:J.

2)FLx prism @ to G) with plastic screw (~). transitorily, in such a position, as shown in Fig. 29, that the end surfaces are coincided.

1?

Coincide tltis cd~cs.

Fig. 29

J)lnsert lenses @ and @ (to be positioned as GiE@T_l_ thicker) into lens chamber(D,

Down

and ftx them with retaining ring@.

4)Attach (D to G) with screws @ x 2 at the center of the hole in (D.

5)Attach(D to G)with screws @xJ.

4-2.Binocular body

l ·2. Reassembly is the sarne as mentioned for the binocular body of B-tube.