DISASSEMBLY PROCEDURE | 1. B·tube 2. F·tube |
|
|
DISASSEMBL Y PROCEOURE
1.B·tube
Release screws @x3, used for attaching main body (D and central axle C@D. and separate the binocular body from the depression prism unit.
1)Binocular body
For disassembly, refer to Fig. 2 and 3, taking the cautions as below:
•To dissolve adhesive No. 350, apply alcohol.
•The other adhesives, not dissolvable with alcohol, is to be removed by striking with a plastic
or wooden hammer. If not removable, break the glass and serape off the adhesive.
eTo separate No. 2002, apply a drop of toluene.
2)Depression prism unit
For disassembly, refer to Fig. 1, taking the cautions as below:
eTo dissolve adhesive No. 350, apply alcohol.
No. 2001 being not dissolvable, use a plastic or wooden hammer. lf not removable, break the glass and scrape off the adhesive.
2.F-tube
Release screws @ x3, and separate the binocular body from the depression prism unit.
1)Binocular body
For disassembly, foilow the sarne procedure as for
2)Depression prism unit
To disassemble the prism unit, refer to Fig. 4, S and 6, taking the cautions as below:
•To dissolve adhesive No. 350, apply alcohol.
No. 2001, No. 921, 501 and 616 being not dissolvable with alcohol. use a plastic or wooden hammer to strike it out. If not removable, break the glass and scrape off the adhesive.
e For dissolving No. 2002, apply a drop of toluene.
eTake off only the upper one of roiler guides @, the lower one being to be remained as fiducial.
- 22 -