DISASSEMBLY PROCEDURE

1. B·tube 2. F·tube

 

 

DISASSEMBL Y PROCEOURE

1.B·tube

Release screws @x3, used for attaching main body (D and central axle C@D. and separate the binocular body from the depression prism unit.

1)Binocular body

For disassembly, refer to Fig. 2 and 3, taking the cautions as below:

To dissolve adhesive No. 350, apply alcohol.

The other adhesives, not dissolvable with alcohol, is to be removed by striking with a plastic

or wooden hammer. If not removable, break the glass and serape off the adhesive.

eTo separate No. 2002, apply a drop of toluene.

2)Depression prism unit

For disassembly, refer to Fig. 1, taking the cautions as below:

eTo dissolve adhesive No. 350, apply alcohol.

No. 2001 being not dissolvable, use a plastic or wooden hammer. lf not removable, break the glass and scrape off the adhesive.

2.F-tube

Release screws @ x3, and separate the binocular body from the depression prism unit.

1)Binocular body

For disassembly, foilow the sarne procedure as for B-tube.

2)Depression prism unit

To disassemble the prism unit, refer to Fig. 4, S and 6, taking the cautions as below:

To dissolve adhesive No. 350, apply alcohol.

No. 2001, No. 921, 501 and 616 being not dissolvable with alcohol. use a plastic or wooden hammer to strike it out. If not removable, break the glass and scrape off the adhesive.

e For dissolving No. 2002, apply a drop of toluene.

eTake off only the upper one of roiler guides @, the lower one being to be remained as fiducial.

- 22 -