R-4108.A

REPAIR ANO ADJUSTMENT

4. Wobbling in X (right and left) Movement

(1 )-b) If a~y dent is found on the guide rails @ , @ , the rollers@ or if the retainer

(})is deformed, replace them with spares.

Procadure

i)Foilow the procedure i), ii) of (1)-a).

ii)Replace dented or deformed parts with spares. ili) Follow the reassembling procedure.

iv)Check wobbling in the X movement.

(i)-c) Dust or soil on teeth of the rack @ and pinion e@ are to be removed by a brush or cleaned by gasoline.

lf they are ínjured, replace them with spares.

Procedure

í) Follow the procedure i) of ( 1)-a).

ii)Remove the rack @ releasing the screws @ x 2.

iii)Remove the handle assembly releasing the screws c@x 2 of the pinion cover

®·

iv)Follow the procedure ii) of the above ( 1)-a).

v)Follow the disassembling procedure 6)-13) (P. 4).

vi)Remove dust and soil by a brush or clean by gasoline. Replace injured parts with spares.

vii)Follow the reassembling procedure.

viii)Check wobbling in the X movement.