Nortel Networks NN46205-310 quick start Installing the 8003, 8006, and 8010 chassis cable guides

Models: NN46205-310

1 82
Download 82 pages 40.24 Kb
Page 37
Image 37

Installing the 8003, 8006, and 8010 chassis cable guides 37

4Add a hex nut to each screw and tighten using a hex wrench.

5Tighten each screw using a Phillips-head screwdriver.

6If the holes in the rack vertical supports require clip nuts, insert a clip nut into each of the 12 locations.

7Lift the 8010co chassis onto the installation shelf.

WARNING

Risk of personal injury

It requires three people to lift the 8010co chassis. To make the chassis lighter, remove the modules and power supplies before you lift it.

8Hold the 8010co chassis in position and align the flanged end of the chassis mounting rail with the six holes on each side of the vertical rack support.

Make sure the hole pairs on each side of the vertical support match horizontally.

9Tighten each screw using a Phillips-head screwdriver.

--End--

Installing the 8003, 8006, and 8010 chassis cable guides

Install the 8003, 8006, and 8010 chassis cable guides to fasten the cable clusters and keep them out of the way.

ATTENTION

Ensure the cable clusters are accessible for maintenance.

Procedure steps