Nortel Networks NN46205-310 quick start Installing DC power modules, Prerequisites

Models: NN46205-310

1 82
Download 82 pages 40.24 Kb
Page 44
Image 44

44Installation

Prerequisites

Ensure the filler panel or cover from the power bay is removed. To remove the filler panel, see “Removing a power filler panel” (page 33).

Procedure steps

Step Action

1Grasp the handle of the new power supply and push the power supply firmly into the bay.

2Tighten the retaining screws until the power supply is firmly seated.

3Connect the power cord to the power supply and to an AC power outlet that is connected to a circuit with no other equipment connections.

--End--

Installing DC power modules

Install the DC power supply module in the leftmost bay to supply DC power to the chassis.

ATTENTION

The 8006 and 8010 chassis have three power supply bays that are numbered 1, 2, and 3 from left to right as viewed from the front of the chassis.

Prerequisites

Verify that you have the following tools and materials:

Cable

Crimping tool for crimping the lugs onto the cable

Heat gun to shrink the tubing around the cable (optional)

Nortel Ethernet Routing Switch 8600

Quick Start

NN46205-310 02.01 Standard

30 May 2008

Copyright © 2008 Nortel Networks

Page 44
Image 44
Nortel Networks NN46205-310 quick start Installing DC power modules, Prerequisites