66Configuration

Procedure job aid: Setup Utility prompt descriptions

 

Prompt

Action

 

 

 

 

Please provide primary

Press Enter to accept the default (/flash/config.cfg),

 

config-file path

or enter a different file location for the primary

 

[/flash/config.cfg]:

configuration file. To store the configuration file

 

 

on the PCMCIA card, use /pcmcia/config.cfg.

 

 

Specifying the path to the file is optional.

 

 

 

 

Please provide

Press Enter to accept the default (/flash/p80a4

 

primary image-file path

1xx.img), or enter a different file location for the

 

[flash/p80a41xx.img]:

primary image file. Specifying the path to the

 

 

file is optional. If the runtime image resides on

 

 

a PCMCIA card, you must specify the path (for

 

 

example /pcmcia/filename).

 

 

 

 

Please add system

Press Enter to accept the default (Ethernet Routing

 

prompt [Ethernet Routing

Switch-8606), or enter a different string of up to 20

 

Switch-8606]:

characters.

 

 

 

 

Please select CPU

Press Enter to accept the default (5), or specify 6

 

Master slot (5/6) [5]:

for the master CPU slot.

 

 

 

 

Master CPU mgmt port:

Press Enter to accept the default(n), or enter

 

autonegotiation [n] (y/n)?

y to indicate that you want the master CPU

 

 

management port to use autonegotiation.

 

 

 

 

speed (10/100) [10]:

Press Enter to accept the default (10 Mbps), or

 

 

specify 100 Mbps.

 

 

 

 

Do you want to enable

Press Enter y if you want the boot and runtime

 

automatic savetostandby

configuration files to be saved on the backup

 

mode [n] (y/n)?

CPU.Press Enter to accept the default (n), if you

 

 

want the boot and runtime configuration files to be

 

 

saved only on the primary CPU.

 

 

 

 

Do you want to enable

Press Enter y if you want the chassis to run in 128

 

m-mode support [n] (y/n)?

K or M mode. Press Enter to accept the default

 

 

(n), if you want it to run in 32 K mode only.

 

 

To run in 128 K mode, the CPU module must be

 

 

an 8691 or higher and the switch must have at

 

 

least one 8600 module (128 K module).

 

 

If you enable m-mode support and you have a

 

 

mixed configuration of modules, the E-modules

 

 

and classic modules are disabled.

 

 

 

 

Do you want to enable

Enter y if you want to enable enhanced operation

 

enhanced operation mode

mode. Accept the default (n), if you do not want to

 

support [n] (y/n)?

enable enhanced operation mode. If you enable

 

 

enhanced operation mode and you have a mixed

 

 

configuration of modules, the classic modules (E-

 

 

or M-modules) are disabled.

 

 

 

 

 

 

Nortel Ethernet Routing Switch 8600

Quick Start

NN46205-310 02.01 Standard

30 May 2008

Copyright © 2008 Nortel Networks