Nortel Networks NN46205-310 quick start Verifying a successful installation, LED power supply

Models: NN46205-310

1 82
Download 82 pages 40.24 Kb
Page 51
Image 51

Verifying a successful installation 51

ATTENTION

The red fan tray fail LED may light briefly while the fans power to operational speed.

--End--

LED power supply

After you turn on the Ethernet Routing Switch 8000 Series, each module automatically initiates a diagnostic test to verify proper module function.

If the power supply LED remains off, do the following:

Procedure steps

Step Action

1Turn the power switch on each power supply to the off position.

2Wait 1 minute.

3Turn the power switch on each power supply to the on position.

--End--

Verifying a successful installation

The following list describes a successful starting sequence for an Ethernet Routing Switch.

When power is applied to the Ethernet Routing Switch 8000, the green LED on each power supply and fan tray or cooling module turns on, and the Online LED for each module is amber.

Each module initiates a self-test, during which time the port and module LEDs display various patterns to indicate the progress of the self-test.

Upon successful completion of the self-test (within 2 or 3 minutes after power is applied to a fully loaded chassis), the module Online LED transitions from amber to green.

After 1 minute of operation, the fan tray Pass LED lights remain green.

If the LEDs on the modules light in this sequence, your installation is successful. Contact your network administrator to verify that the Ethernet Routing Switch 8000 is connected to the network.

Nortel Ethernet Routing Switch 8600

Quick Start

NN46205-310 02.01 Standard

30 May 2008