CompoBus/D Communications Card Operations

 

 

 

Chapter 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Constant

Name

Regis-

Setting

Setting

Default

Chang

 

Control mode setting

 

 

 

 

ter No.

unit

range

setting

es dur-

 

 

 

 

 

 

 

 

 

V/f

 

V/f with

Open

 

Flux

 

 

 

 

 

 

ing op-

 

 

 

 

 

 

 

 

control

 

PG

loop

 

vector

 

 

 

 

 

 

eration

 

 

 

 

 

 

 

 

 

 

 

vector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b2-04

DC injection braking

018A

0.01

0.00 to 10.00

0.50

No

Yes

 

Yes

Yes

 

Yes

 

time at stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3-01

Speed search

018E

1

0, 1

0 (See

No

Yes

 

Yes

Yes

 

Yes

 

selection at start

 

 

 

note.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3-02

Speed search

018F

1

0 to 200

100

No

Yes

 

No

Yes

 

No

 

operation current

 

 

 

(See

 

 

 

 

 

 

 

 

 

 

 

 

 

note.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3-03

Speed search

0190

0.1

0.1 to 10.0

2.0

No

Yes

 

No

Yes

 

No

 

deceleration time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4-01

Timer function

0192

0.1

0.0 to 300.0

0.0

No

Yes

 

Yes

Yes

 

Yes

 

ON-delay time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4-02

Timer function

0193

0.1

0.0 to 300.0

0.0

No

Yes

 

Yes

Yes

 

Yes

 

OFF-delay time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-01

PID control selection

0194

1

0 to 2

0

No

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-02

Proportional gain (P)

0195

0.01

0.00 to 25.00

1.00

Yes

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-03

Integral time (I)

0196

0.1

0.0 to 360.0

1.0

Yes

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-04

Integral limit (I)

0197

0.1

0.0 to 100.0

100.0

Yes

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-05

Differential time (D)

0198

0.01

0.00 to 10.00

0.00

Yes

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-06

PID limit

0199

0.1

0.0 to 100.0

100.0

Yes

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-07

PID offset adjustment

019A

0.1

–100.0 to

0.0

Yes

Yes

 

Yes

Yes

 

Yes

 

 

 

 

100.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5-08

PID primary delay

019B

0.01

0.00 to 10.00

0.00

Yes

Yes

 

Yes

Yes

 

Yes

 

time constant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6-01

Dwell frequency at

019C

0.1

0.0 to 400.0

0.0

No

Yes

 

Yes

Yes

 

Yes

 

start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6-02

Dwell time at start

019D

0.1

0.0 to 10.0

0.0

No

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6-03

Dwell frequency at

019E

0.1

0.0 to 400.0

0.0

No

Yes

 

Yes

Yes

 

Yes

 

stop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6-04

Dwell time at stop

019F

0.1

0.0 to 10.0

0.0

No

Yes

 

Yes

Yes

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7-01

Droop control gain

01A0

0.1

0.0 to 100.0

0.0

Yes

No

 

No

No

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7-02

Droop control delay

01A1

0.01

0.03 to 2.00

0.05

Yes

No

 

No

No

 

Yes

 

time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b8-01

Energy-saving gain

01A2

1

0 to 100

80

No

Yes

 

Yes

No

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b8-02

Energy-saving

01A3

0.1

0.0 to 400.0

0.0

No

Yes

 

Yes

No

 

No

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b9-01

Zero-servo gain

01A4

1

0 to 100

5

No

No

 

No

No

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b9-02

Zero-servo

01A5

1

0 to 16,383

10

No

No

 

No

No

 

Yes

 

completion width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note When the control mode is changed, the Inverter will revert to default settings. (The open loop vec- tor control default setting will be displayed.)

5-40

Page 102
Image 102
Omron 3G3FV-PDRT1-SIN user manual Chapter

3G3FV-PDRT1-SIN specifications

The Omron 3G3FV-PDRT1-SIN is a highly sophisticated variable frequency drive (VFD) designed to enhance energy efficiency and drive performance in various industrial applications. This particular model is part of the Omron 3G3FV series, which is well-regarded for its reliability, versatility, and ease of use.

One of the main features of the 3G3FV-PDRT1-SIN is its ability to control asynchronous motors efficiently. The drive supports a wide range of motor types, making it suitable for diverse applications across different sectors, including manufacturing, HVAC systems, and material handling. The unit is designed to provide precise control over the speed and torque of motors, which is crucial for optimizing machine performance and energy consumption.

The 3G3FV-PDRT1-SIN incorporates advanced technologies such as vector control and high-performance algorithms. These technologies allow for superior motor control, enabling the drive to maintain accurate speed and torque under varying loads. This functionality is essential for applications that require consistent performance, particularly in processes that demand high precision and responsiveness.

Additionally, the drive features an easy-to-use graphical display, which simplifies the programming and monitoring of drive settings. Users can quickly configure the operating parameters and monitor performance metrics, enhancing operational efficiency. The intuitive interface also allows for quick troubleshooting, reducing downtime and maintenance costs.

The Omron 3G3FV-PDRT1-SIN is built with robustness and durability in mind. It conforms to several international standards, ensuring reliable operation in industrial settings. The drive is designed to withstand harsh environments, including fluctuations in temperature and humidity. This resilience helps to extend the lifespan of both the drive and the connected motor.

Furthermore, the 3G3FV series includes built-in communication capabilities that facilitate integration with other automation equipment. This connectivity supports various industrial protocols, enabling seamless data exchange and real-time monitoring of system performance.

In conclusion, the Omron 3G3FV-PDRT1-SIN is an advanced variable frequency drive that combines energy efficiency, precision control, and robust design. It is an ideal solution for optimizing motor-driven systems across a range of industrial applications, with features that enhance user experience and overall operational effectiveness.