Communications Programs (SYSMAC C200HX/HG/HE PCs)

Chapter 7

 

 

 

HLadder Program

01000 (Program Start Input Bit)

DIFU (013)

01001

01001

01001

MOVD (083)

DM0007

#0012

25506 (Equals Flag)

BSET (071)

#0000

DM0200

DM0220

DVB (053)

DM0002

#0002

DM0200

CMP (020)

#0000

DM0201

ADB (050)

#0001

DM0200

DM0200

ADB (050)

#0004

DM0200

DM0200

BCD (024)

DM0200

DM0202

MOVD (083)

DM0005

#0210

DM0203

MOVD (083)

DM0006

#0012

DM0203

MOVD (083)

DM0204

MOVD (083)

DM0007

#0210

DM0205

MOVD (083)

DM0008

#0012

DM0205

MOVD (083)

DM0008

#0210

DM0206

MOVD (083)

DM0009

#0012

DM0206

MOVD (083)

DM0000

#0210

DM0210

ORW (035)

DM0210

DM0001

DM0220

BSET (071)

#0000

DM2000

DM2009

MOV (021)

DM0006

#0210

DM0204

#0001

000

Converts to IOWR instruction data from the specified DM areas (DM 0000 to DM 0009).

Clears the data storage area.

Sets the 000 word used for shift register to “1.”