Omron 3G3FV-PDRT1-SIN user manual Control Supervisor Objects Class 29 Hex, Object Details

Models: 3G3FV-PDRT1-SIN

1 161
Download 161 pages 943 b
Page 79
Image 79

CompoBus/D Communications Card Operations

Chapter 5

 

 

 

HObject Details

Instance

Attribute

Name

Content

Setting range

Default

Read

Write

Size

 

 

 

 

 

 

 

 

 

 

00

 

01

Object Software

Indicates class 28 software

---

0001

Yes

No

Word

 

 

 

Revision

revisions. The revision value is

 

 

 

 

 

 

 

 

 

advanced whenever there is a

 

 

 

 

 

 

 

 

 

change.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

 

03

Motor Type

Indicates the type of motor to be

---

07

Yes

No

Byte

 

 

 

 

used. The setting for a

 

 

 

 

 

 

 

 

 

squirrel-cage inductive motor is 7.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

Motor Rated

The motor’s rated current can be

Inverter rated

See

Yes

Yes

Word

 

 

 

Current

set and read. The setting unit is

output current

note 1.

 

 

 

 

 

 

 

0.1 A. (The setting unit can be

10% to 120%

 

 

 

 

 

 

 

 

changed using the current scale

 

 

 

 

 

 

 

 

 

in Class 2A, Instance 1, Attribute

 

 

 

 

 

 

 

 

 

17.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

Motor Rated

The motor’s rated voltage can be

0 to 255 V

00C8

Yes

Yes

Word

 

 

 

Voltage

set and read. The setting unit is 1

(0 to 510 V)

(0190)

 

 

 

 

 

 

 

V. (The setting unit can be

See note 2.

See

 

 

 

 

 

 

 

changed using the voltage scale

 

 

 

 

 

 

 

 

note 2.

 

 

 

 

 

 

 

in Class 2A, Instance 1, Attribute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1B.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

1. The default setting for the motor’s rated current depends on the Inverter model.

 

 

 

Example: 1.90A (0013 hex) for 200-V class, 0.4 kW

 

 

 

 

Note

2. The figures enclosed in parentheses in the “Setting range” and “Default” columns are the val-

 

 

ues for 400-V class Inverters.

 

 

 

 

 

5-2-6 Control Supervisor Objects: Class 29 Hex

Control supervisor objects are objects that have Inverter control I/O-related functions. They are as- signed according to their particular control I/O functions, such as forward operation, reverse operation, error detection, and so on. Be careful when setting up a remote I/O communications connection. These functions are shared with similar functions used for remote I/O, so even if they have been set for mes- sage operations they may get rewritten for remote I/O.

HSupport Service Codes

Service Code No. (Hex)

Service

 

 

0E

Get attribute single

 

 

10

Set attribute single

 

 

05

Reset attribute

 

Turns OFF the Forward Operation and Reverse Operation inputs and turns

 

ON the Fault Reset. Then turns OFF the Fault Reset when Inverter Ready

 

is output.

5-17

Page 79
Image 79
Omron 3G3FV-PDRT1-SIN user manual Control Supervisor Objects Class 29 Hex, Object Details, Support Service Codes