Omron 3G3FV-PDRT1-SIN user manual Chapter

Models: 3G3FV-PDRT1-SIN

1 161
Download 161 pages 943 b
Page 154
Image 154

Appendices

 

 

 

 

 

Chapter 8

 

 

 

 

 

 

 

 

 

 

Instance

Attribute

Name

Content

Setting

Default

Read

Write

Size

 

 

 

 

range

(Hex)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

07

Produced connection

Indicates the maximum

---

0004

Yes

No

Word

Remote

 

size

number of bytes for

 

 

 

 

 

 

I/O

 

 

transmission.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

Consumed connection

Indicates the maximum

---

0004

Yes

No

Word

 

 

size

number of bytes for

 

 

 

 

 

 

 

 

 

reception.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09

Expected packet rate

Indicates the length of the

0 to

0000

Yes

Yes

Word

 

 

 

internal processing timeout

65,535

(0 ms)

 

 

 

 

 

 

 

when a communications

(ms)

 

 

 

 

 

 

 

 

request is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0C

Watchdog time-out

Indicates the action for

---

01

Yes

No

Byte

 

 

action

internal processing timeout

 

 

 

 

 

 

 

 

 

related to communications.

 

 

 

 

 

 

 

 

 

00: Retain timeout status

 

 

 

 

 

 

 

 

 

(until reset or cleared).

 

 

 

 

 

 

 

 

 

01: Cut connection

 

 

 

 

 

 

 

 

 

automatically.

 

 

 

 

 

 

 

 

 

02: Operate again with

 

 

 

 

 

 

 

 

 

same connection as is.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0D

Produced connection

Indicates number of bytes

---

0003

Yes

No

Word

 

 

path length

of data for produced

 

 

 

 

 

 

 

 

 

connection path.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0E

Produced connection

Indicates the data for

---

62 34 37

Yes

No

Array

 

 

path

defining the application

 

 

 

 

 

 

 

 

 

object for sending this

 

 

 

 

 

 

 

 

 

object (instance).

 

 

 

 

 

 

 

 

 

Note: Has a function for

 

 

 

 

 

 

 

 

 

switching the CompoBus/D

 

 

 

 

 

 

 

 

 

Communication Card’s

 

 

 

 

 

 

 

 

 

remote I/O operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0F

Consumed connection

Indicates the number of

---

0003

Yes

No

Word

 

 

path length

bytes of data for the

 

 

 

 

 

 

 

 

 

consumed connection path.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Consumed connection

Indicates the data for

---

62 31 35

Yes

No

Array

 

 

path

defining the application

 

 

 

 

 

 

 

 

 

object for receiving this

 

 

 

 

 

 

 

 

 

object (instance).

 

 

 

 

 

 

 

 

 

Note: Has a function for

 

 

 

 

 

 

 

 

 

switching the CompoBus/D

 

 

 

 

 

 

 

 

 

Communication Card’s

 

 

 

 

 

 

 

 

 

remote I/O operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note “Reception” means output (3G3FV to SYSMAC PC), and “transmission” means input (SYSMAC PC to 3G3FV).

8-10

Page 154
Image 154
Omron 3G3FV-PDRT1-SIN user manual Chapter