Omron 3G3FV-PDRT1-SIN DeviceNet Objects Class 03 Hex, Service Code No. Hex Get attribute single

Models: 3G3FV-PDRT1-SIN

1 161
Download 161 pages 943 b
Page 149
Image 149

Appendices

Chapter 8

 

 

 

HSupport Service Code

Service Code No. (Hex)

Service

 

 

0E

Get attribute single

HObject Details

Instance

Attribute

Name

Content

Setting

Default

Read

Write

Size

 

 

 

 

range

(Hex)

 

 

 

 

 

 

 

 

 

 

 

 

00

01

Object Software

Indicates class 02 software

---

0001

Yes

No

Word

 

 

Revision

revisions. The revision

 

 

 

 

 

 

 

 

value is advanced

 

 

 

 

 

 

 

 

whenever there is a

 

 

 

 

 

 

 

 

change.

 

 

 

 

 

8-2-3 DeviceNet Objects: Class 03 Hex

DeviceNet objects are objects related to CompoBus/D (DeviceNet) communications information and operations.

HSupport Service Code

Service Code No. (Hex)

Service

 

 

0E

Get attribute single

 

 

10

Set attribute single

HObject Details

Instance

Attribute

Name

 

Content

Setting

Default

Read

Write

Size

 

 

 

 

 

range

(Hex)

 

 

 

 

 

 

 

 

 

 

 

 

00

01

Object Software

Indicates class 03 software

---

0001

Yes

No

Word

 

 

Revision

revisions. The revision

 

 

 

 

 

 

 

 

value is advanced

 

 

 

 

 

 

 

 

whenever there is a

 

 

 

 

 

 

 

 

change.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

01

MAC ID

Indicates the set value of

---

00

Yes

No

Byte

 

 

 

the communications node

 

 

 

 

 

 

 

 

address. It is read-only

 

 

 

 

 

 

 

 

because the setting is

 

 

 

 

 

 

 

 

made by the external

 

 

 

 

 

 

 

 

setting switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

Baud Rate

Indicates the baud rate. It is

---

00

Yes

No

Byte

 

 

 

write-protected because the

 

 

 

 

 

 

 

 

setting is made by the

 

 

 

 

 

 

 

 

external setting switch.

 

 

 

 

 

 

 

 

00: 125 Kbps

 

 

 

 

 

 

 

 

01: 250 Kbps

 

 

 

 

 

 

 

 

02: 500 Kbps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05

Allocation Information

Indicates DeviceNet

---

0000

Yes

No

Byte 2

 

 

 

communications connection

 

 

 

 

 

 

 

 

information. Used to check

 

 

 

 

 

 

 

 

whether connection is

 

 

 

 

 

 

 

 

already made.

 

 

 

 

 

 

 

 

See details below.

 

 

 

 

 

 

 

 

Cannot be written for ex-

 

 

 

 

 

 

 

 

 

plicit messages. (Error is

 

 

 

 

 

 

 

 

 

returned.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-5

Page 149
Image 149
Omron 3G3FV-PDRT1-SIN user manual DeviceNet Objects Class 03 Hex, Service Code No. Hex Get attribute single