Omron 3G3FV-PDRT1-SIN user manual Program-related Bits Used, Inverter Control Input

Models: 3G3FV-PDRT1-SIN

1 161
Download 161 pages 943 b
Page 133
Image 133

Communications Programs (SYSMAC C200HX/HG/HE PCs)

Chapter 7

 

 

 

DProgram-related Bits Used

Word

Function

 

 

00000

Program Start Input Bit

 

 

00001

Program End Input Bit

 

 

00002

Program Execution Flag

 

 

00003

Communications Error Reset Input Bit

 

 

00004

Inverter Stop Command Flag

 

 

01000

Frequency Reference Write Flag

 

 

00101

Control Input Write Flag

 

 

00102

Output Frequency Read Flag

 

 

00103

Inverter Status Read Flag

 

 

00300

Frequency Reference Write Completed Flag

 

 

00301

Control Input Write Completed Flag

 

 

00302

Output Frequency Read Completed Flag

 

 

00303

Inverter Status Read Completed Flag

 

 

03110

Communications Error Flag

DInverter Control Input

Word

Function

 

 

DM1000

Reference frequency setting

 

 

DM2000

Output frequency monitor

DRemote I/O Allocation Areas

I/O classification

Word address

15 to 8

7 to 0

 

 

 

 

Output

n

Register No. (leftmost bits)

Function code (10: Write, 03:

(PC to 3G3FV

 

 

Read)

Inverter)

 

 

 

n+1

Register data (leftmost bits)

Register No. (rightmost bits)

 

 

 

 

 

 

n+2

Not used

Register data (rightmost bits)

 

 

 

 

Input

m

Register No. (leftmost bits)

Function code (10: Write, 03:

(3G3FV Inverter

 

 

Read)

to PC)

 

 

 

m+1

Register data (leftmost bits)

Register No. (rightmost bits)

 

 

 

 

 

 

m+2

Not used

Register data (rightmost bits)

7-14

Page 133
Image 133
Omron 3G3FV-PDRT1-SIN user manual Program-related Bits Used, Inverter Control Input, Remote I/O Allocation Areas