Omron 3G3FV-PDRT1-SIN user manual Reading Parameter Data, Allocation

Models: 3G3FV-PDRT1-SIN

1 161
Download 161 pages 943 b
Page 138
Image 138

Communications Programs (SYSMAC C200HX/HG/HE PCs)

Chapter 7

00004

 

 

 

 

MOV (021)

#0000

001

MOV (021)

#0010

DM0100

MOV (021)

#0000

DM0101

MOV (021)

#0000

DM0102

XFER (070)

#0002

DM0100

n

MOVD (083)

DM0102

#0010

n+2

Executes stop command.

7-3-2 Reading Parameter Data

This programming example is designed to read the parameter data specified in the 3G3FV Inverter. To use special remote I/O, it is necessary to switch the remote I/O operation. Refer to 5-3 Switching Re- mote I/O Operation and change to the special remote I/O operation.

HAllocation

Bit

Bit

Bit

Bit

Bit

00000

00002

03000

03001

03005

DM 0000

DM 0001

Read Parameter Input Bit

Faulty Data Reset Input Bit

Data Read Flag

Faulty Data Flag

Data Read Completed Flag

Register number of the parameter to be read

Read data

7-19