Error Codes

The following error codes are displayed in the display window if an error occurs in the camera:

Confirm the type of warning and refer to the details in the [Warning Description Tables] (page 145) for countermeasures.

Code No.

Description

 

Type of warnings

 

 

 

 

 

 

E-11

Video initialisation error

1.

System Errors

 

 

 

 

 

 

E-27

Recording control error

1.

System Errors

 

 

 

 

 

 

E-30

P2 card removal error

2.

Card removal error

 

 

 

 

 

 

E-34

LCD microcontroller error

1.

System Errors

 

 

 

 

 

 

E-38

P2 streaming microcontroller error

1.

System Errors

 

 

 

 

 

E-39

Abnormal initialization of the AVC-Intra codec board (optional AJ-YBX200G)

1. System Errors

 

 

 

 

 

E-3F

Microprocessor error in the camera control circuit.

1. System Errors

 

 

 

 

 

 

E-40

Image sequence error (in case of 24P, 30P and 25P)

6.

Image Sequence Error (24P, 30P, 25P)

 

 

 

 

 

E-63

Something is wrong with the system control microprocessor.

1. System Errors

 

 

 

 

 

E-6F

Reference signal error.

1. System Errors

 

 

 

 

00:00:00:11

Recording error on a P2 card

7.

Recording Error

 

 

 

 

 

 

 

 

 

 

 

1394 Error Codes

 

 

 

 

 

 

 

Code No.

Description

Recording

Indication in display

window

 

 

 

 

 

 

 

 

Signals being input to the DVCPRO/DV

Stops

 

1394 E-80

connector are not 1a speed transfer

 

 

 

signals in DV format.

 

 

 

 

 

 

 

Signals being input to the DVCPRO/DV

Stops

 

1394 E-81

connector are not 1a speed transfer

 

 

 

signals in DVCPRO (25 Mbps) format.

 

 

 

 

 

 

 

Signals being input to the DVCPRO/DV

Stops

 

1394 E-82

connector are not 1a speed transfer

 

 

 

signals in DVCPRO50 (50 Mbps) format.

 

 

 

 

 

 

1394 E-83

Incorrect signals are being input to the

Stops

 

DVCPRO/DV connector.

 

 

 

 

 

 

 

 

 

 

Signals being input to the DVCPRO/DV

Stops

 

1394 E-84

connector are not in DVCPRO or DV

 

 

 

format.

 

The time code section of the

 

 

 

 

Signals being input to the DVCPRO/DV

Stops

 

display window indicates the

1394 E-85

connector are not 1x speed transfer signals

 

 

appropriate error code that

 

in DVCPRO HD format.

 

 

 

blinks every two seconds.

 

 

 

1394 E-87

Incorrect audio signals are being input to

Continues with no sound.

 

the DVCPRO/DV connector.

 

 

 

 

 

 

 

 

 

 

No signal is supplied to the DVCPRO/DV

While the recording mode continues, no

 

 

connector.

data is recorded on cards unless the

 

1394 E-90

 

abnormal condition is corrected. If an

 

 

 

error has occurred before recording, then,

 

 

 

recording does not start.

 

 

 

 

 

 

With the menu option REC MODE set to

Stops

 

1394 E-91

DV, copy guard information signals for

 

 

recording prohibited data are being input to

 

 

 

 

 

 

the DVCPRO/DV connector.

 

 

 

 

 

 

 

The DVCPRO/DV connector is not properly

No recording in 1394 input mode can be

 

1394 E-92

connected. The viewfinder indicates the

performed.

 

 

message "1394 INITIAL ERROR."

 

 

 

 

 

 