Externally Locking the Time Code

The unit’s internal time code generator can be locked to an

Example 2: When connecting a multiple number of units

external generator. In addition, the external time code

and using one of them as the reference unit

generator can be locked to the unit’s internal generator.

 

Example of connections for external locking

As the figure shows, connect both the reference video signal and reference time code.

Example 1: When locking onto an external signal

Reference time

code

TC IN

GENLOCK IN

Reference video

signal

‹Note

In place of the HD Y reference signal, composite video signals can be input as the reference video signal.

 

TC OUT

MON OUT or

Reference unit

VIDEO OUT

 

(VBS)

 

 

TC IN

 

GENLOCK IN

TC OUT

MON OUT or

VIDEO OUT

(VBS)

TC IN

GENLOCK IN

MON OUT or

VIDEO OUTTC OUT (VBS)

To the next camera

‹Note

The system can be configured with multiple units by opening the <GENLOCK> screen from the SYSTEM SETTING page and setting the GL PHASE item to the connector using menu operations.

The phase of the time code can correspond to either the HDY output signals of the MON OUT connector or VBS output signals of the VIDEO OUT and MON OUT connector.

However, the same value should commonly be set to the GL PHASE for all cameras. If different values coexist in the system, the shooting timing may not correspond to each other.

Reference video signal

Setting of GL PHASE

 

 

MON OUT (VBS) or

COMPOSIT

VIDEO OUT (VBS)

 

 

 

Setting of GL PHASE

Item

Variable

Remarks

range

 

 

 

 

 

GL PHASE

HD SDI

For selecting the output signals that

 

COMPOSIT

lock phases to the signals that are

 

 

input in the GENLOCK IN connector.

 

 

HD SDI:

 

 

For locking the HD SDI signals to

 

 

the GENLOCK input.

 

 

For the down converter output

 

 

signals, the start position of the

 

 

video delays by about 90 lines.

 

 

COMPOSIT:

 

 

For locking the down converter

 

 

output signals to the GENLOCK

 

 

input.

 

 

For the HD SDI output signals, the

 

 

start position of the video gains by

 

 

about 90 lines.

 

 

 

62 Adjustments and Settings for Recording : Setting Time Data