Items/

Adjustable

Remarks

Data Saved

Range

 

 

 

 

PAG L95

¢

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

: Disable selection.

 

 

 

 

 

AUTO

Select auto or manual to set the NEAR

 

 

 

 

 

MANUAL

END voltage.

 

 

 

 

 

 

AUTO: Set voltage automatically.

 

 

 

 

 

 

MANUAL:Set voltage manually.

 

 

 

 

 

 

 

 

 

 

 

 

11.0

When MANUAL is selected in the menu

 

 

 

 

 

:

above, set the NEAR END voltage in 0.1

 

 

 

 

 

13.5

V steps.

 

 

 

 

 

:

 

 

 

 

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

BP

-GL65/95

¢

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

: Disable selection.

 

 

 

 

 

AUTO

Select auto or manual to set the NEAR

 

 

 

 

 

MANUAL

END voltage.

 

 

 

 

 

 

AUTO: Set voltage automatically.

 

 

 

 

 

 

MANUAL:Set voltage manually.

 

 

 

 

 

 

 

 

 

 

 

 

11.0

When MANUAL is selected in the menu

 

 

 

 

 

:

above, set the NEAR END voltage in 0.1

 

 

 

 

 

13.5

V steps.

 

 

 

 

 

:

 

 

 

 

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

BATTERY SETTING2

 

Items/

Adjustable

Remarks

Data Saved

Range

 

 

 

 

 

NiCd14

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

NEAR END

11.0

Set the NEAR END voltage in 0.1 V

 

 

 

 

 

:

 

steps.

 

 

 

 

 

13.8

 

 

 

 

 

 

:

 

 

 

 

 

 

 

15.0

 

 

END

11.0

Set the END voltage in 0.1 V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

13.4

 

 

 

 

 

 

:

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

TYPE A

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

FULL

12.0

 

Set the voltage to display the FULL

 

 

 

 

 

:

 

indication in 0.1 V steps.

 

 

 

 

 

15.1

 

 

 

 

 

 

:

 

 

 

 

 

 

 

17.0

 

 

NEAR END

11.0

Set the NEAR END voltage in 0.1 V

 

 

 

 

 

:

 

steps.

 

 

 

 

 

13.6

 

 

 

 

 

 

:

 

 

 

 

 

 

 

15.0

 

 

END

11.0

Set the END voltage in 0.1 V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

12.9

 

 

 

 

 

 

:

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

TYPE B

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

FULL

12.0

 

Set the voltage to display the FULL

 

 

 

 

 

:

 

indication in 0.1 V steps.

 

 

 

 

 

15.5

 

 

 

 

 

 

:

 

 

 

 

 

 

 

17.0

 

 

NEAR END

11.0

Set the NEAR END voltage in 0.1 V

 

 

 

 

 

:

 

steps.

 

 

 

 

 

13.5

 

 

 

 

 

 

:

 

 

 

 

 

 

 

15.0

 

 

END

11.0

Set the END voltage in 0.1 V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

13.1

 

 

 

 

 

 

:

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

zThe remaining battery level is indicated in percentage when a battery with this function is installed on the unit.

The ____ in the Adjustable Range column indicates the preset mode.

180 Menu : Menu Description Tables