Chapter 8 Menu Description Tables (continued)
| Items/ | Adjustable | Remarks | ||||
Data Saved | Range | ||||||
| |||||||
|
|
| |||||
DIONIC90 | _ | Enable selection under BATTERY | |||||
|
|
|
|
| • | SELECT. | |
|
|
|
|
|
| _:Enable selection. | |
|
|
|
|
|
| • :Disable selection. | |
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR | |
|
|
|
|
| AUTO | END voltage. | |
|
|
|
|
|
| MANUAL: Set voltage manually. | |
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
| 11.0 | When MANUAL is selected in the menu | |
|
|
|
|
| : | above, set the NEAR END voltage in | |
|
|
|
|
| 13.6 | 0.1 V steps. | |
|
|
|
|
| : | ||
|
|
|
|
|
| ||
– | C | U | F | – | 15.0 |
| |
|
|
|
|
|
|
| |
| DIONIC160 | _ | Enable selection under BATTERY | ||||
|
|
|
|
| • | SELECT. | |
|
|
|
|
|
| _:Enable selection. | |
|
|
|
|
|
| • :Disable selection. | |
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR | |
|
|
|
|
| AUTO | END voltage. | |
|
|
|
|
|
| MANUAL: Set voltage manually. | |
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
| 11.0 | When MANUAL is selected in the menu | |
|
|
|
|
| : | above, set the NEAR END voltage in | |
|
|
|
|
| 13.3 | 0.1 V steps. | |
|
|
|
|
| : | ||
|
|
|
|
|
| ||
– | C | U | F | – | 15.0 |
| |
|
|
|
|
|
|
| |
HP |
|
|
| _ | Enable selection under BATTERY | ||
|
|
|
|
| • | SELECT. | |
|
|
|
|
|
| _:Enable selection. | |
|
|
|
|
|
| • :Disable selection. | |
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR | |
|
|
|
|
| AUTO | END voltage. | |
|
|
|
|
|
| MANUAL: Set voltage manually. | |
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
|
|
| |
|
|
|
|
| 11.0 | When MANUAL is selected in the menu | |
|
|
|
|
| : | above, set the NEAR END voltage in | |
|
|
|
|
| 12.8 | 0.1 V steps. | |
|
|
|
|
| : | ||
|
|
|
|
|
| ||
– | C | U | F | – | 15.0 |
| |
|
|
|
|
|
|
| |
BP | _ | Enable selection under BATTERY | |||||
|
|
|
|
| • | SELECT. | |
|
|
|
|
|
| _:Enable selection. | |
|
|
|
|
|
| • :Disable selection. | |
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR | |
|
|
|
|
| AUTO | END voltage. | |
|
|
|
|
|
| MANUAL: Set voltage manually. | |
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
| 11.0 | When MANUAL is selected in the menu | |
|
|
|
|
| : | above, set the NEAR END voltage in | |
|
|
|
|
| 11.5 | 0.1 V steps. | |
|
|
|
|
| : | ||
|
|
|
|
|
| ||
– | C | U | F | – | 15.0 |
| |
|
|
|
|
|
|
| |
NP |
|
|
| _ | Enable selection under BATTERY | ||
|
|
|
|
| • | SELECT. | |
|
|
|
|
|
| _:Enable selection. | |
|
|
|
|
|
| • :Disable selection. | |
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR | |
|
|
|
|
| AUTO | END voltage. | |
|
|
|
|
|
| MANUAL: Set voltage manually. | |
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
| 11.0 | When MANUAL is selected in the menu | |
|
|
|
|
| : | above, set the NEAR END voltage in | |
|
|
|
|
| 13.3 | 0.1 V steps. | |
|
|
|
|
| : | ||
|
|
|
|
|
| ||
– | C | U | F | – | 15.0 |
| |
|
|
|
|
|
|
|
| Items/ | Adjustable | Remarks |
|
| |||
Data Saved | Range |
|
| |||||
|
|
| ||||||
|
|
|
|
| ||||
ENDURA50 | _ | Enable selection under BATTERY |
|
| ||||
|
|
|
|
| • | SELECT. |
|
|
|
|
|
|
|
| _:Enable selection. |
|
|
|
|
|
|
|
| • :Disable selection. |
|
|
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR |
|
|
|
|
|
|
| AUTO | END voltage. |
|
|
|
|
|
|
|
| MANUAL: Set voltage manually. |
|
|
|
|
|
|
|
| AUTO: Set voltage automatically. |
|
|
|
|
|
|
| 11.0 | When MANUAL is selected in the menu |
|
|
|
|
|
|
| : | above, set the NEAR END voltage in |
|
|
|
|
|
|
| 13.1 | 0.1 V steps. |
|
|
|
|
|
|
| : |
|
| |
|
|
|
|
|
|
|
| |
– | C | U | F | – | 15.0 |
|
|
|
|
|
|
|
|
|
|
|
|
ENDURA80 | _ | Enable selection under BATTERY |
|
| ||||
|
|
|
|
| • | SELECT. |
|
|
|
|
|
|
|
| _:Enable selection. |
|
|
|
|
|
|
|
| • :Disable selection. |
|
|
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR |
|
|
|
|
|
|
| AUTO | END voltage. |
| 8 |
|
|
|
|
|
| MANUAL: Set voltage manually. |
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| AUTO: Set voltage automatically. |
|
|
|
|
|
|
| 11.0 | When MANUAL is selected in the menu |
|
|
|
|
|
|
| : | above, set the NEAR END voltage in |
|
|
|
|
|
|
| 13.5 | 0.1 V steps. |
|
|
|
|
|
|
| : |
|
| |
|
|
|
|
|
|
|
| |
– | C | U | F | – | 15.0 |
|
|
|
|
|
|
|
|
|
|
|
|
BP | _ | Enable selection under BATTERY |
|
| ||||
|
|
|
|
| • | SELECT. |
|
|
|
|
|
|
|
| _:Enable selection. |
|
|
|
|
|
|
|
| • :Disable selection. |
|
|
|
|
|
|
| MANUAL | Select auto or manual to set the NEAR |
|
|
|
|
|
|
| AUTO | END voltage. |
|
|
|
|
|
|
|
| MANUAL: Set voltage manually. |
|
|
|
|
|
|
|
| AUTO: Set voltage automatically. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 11.0 | When MANUAL is selected in the menu |
|
|
|
|
|
|
| : | above, set the NEAR END voltage in |
|
|
|
|
|
|
| 11.2 | 0.1 V steps. |
|
|
|
|
|
|
| : |
|
| |
|
|
|
|
|
|
|
| |
– | C | U | F | – | 15.0 |
|
|
|
|
|
|
|
|
|
|
|
|
<Note>
The remaining battery capacity for digital batteries is displayed as % inside the viewfinder (PRO14/TRIM14/ HYTRON50/HYTRON100/HYTRON120/DIONIC90/
The BATT NEAR END alarm, however, is triggered according to the setting on the <BATTERY SETTING1> screen, regardless of the % indication.
The ____ in the Adjustable Range column indicates the preset mode.