Chapter 7 Maintenance and Inspections (continued)

9. Battery Nearly Empty

Display window

One of the bars in the battery remaining

indication

indicator starts blinking.

 

 

WARNING lamp

Blinks once per second.

 

 

Tally lamp

Blinks once per second.

 

 

Viewfinder

The BATT LED blinks.

 

 

Warning tone

Beeps 4 times per second.

 

 

Warning

The battery is about to run out.

description

 

 

 

Recording/

Continues to operate.

playback operation

 

 

Countermeasures

Replace the battery as required.

 

 

7-3-2 Error Codes

The following error codes are displayed in the display window if an error occurs in the camera:

Code No.

Description

 

 

E-11

Video initialisation error

 

 

E-27

Recording control error

 

 

E-30

P2 card removal error

 

 

E-38

P2 streaming microcontroller error

 

 

E-3F

Microprocessor error in the camera control circuit.

 

 

E-6F

Reference signal error.

 

 

10. P2 Card Nearly Full

 

 

 

 

 

7

 

 

 

 

 

 

 

 

Display window

One of the bars for remaining MEDIA

 

 

 

indication

capacity starts blinking.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING lamp

Blinks once

per

second

while

recording

 

 

continues.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tally lamp

Blinks once

per

second

while

recording

 

 

continues.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Viewfinder

The P2

card

remaining capacity

indicator

 

 

blinks.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning tone

Beeps

once

per

second

while

recording

 

 

continues.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

The total remaining capacity of all the P2

 

 

description

cards is two minutes or less.

 

 

 

 

 

 

 

 

 

 

 

 

 

Recording/

Continues to operate.

 

 

 

 

playback operation

 

 

 

 

 

 

 

Countermeasures

Replace the cards. If there is an empty card

 

 

slot, insert a new card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11. P2 Card Error

 

 

 

 

 

 

 

 

 

 

If the error occurs during recording,

 

 

 

“00:0000:11” appears as the time code

 

Display window

indication. The indication continues to flash

 

indication

after recording is stopped and until the next

 

 

operation is

performed.

There is no

 

 

indication if the error occurs during playback.

 

 

 

 

 

If the error occurs during recording, the lamp

 

 

WARNING lamp

flashes four times per second for a period of

 

about three seconds. The lamp does not

 

 

 

 

 

light if the error occurs during playback.

 

 

 

 

 

If the error occurs during recording, the lamp

 

 

Tally lamp

flashes four times per second for a period of

 

about three seconds. The lamp does not

 

 

 

 

 

light if the error occurs during playback.

 

 

 

 

 

A flashing “CARD ERR _” appears. In the

 

 

Viewfinder

actual indication the _ is replaced by the slot

 

number of the P2 card that triggered the

 

 

 

 

 

error.

 

 

 

 

 

 

 

 

 

 

 

If the error occurs during recording, the tone

 

 

Warning tone

sounds four times per second for a period of

 

about three seconds. The tone does not

 

 

 

 

 

sound if the error occurs during playback.

 

 

 

 

Warning

An error has occurred while recording data

 

 

description

to or playing data from a P2 card.

 

 

 

 

 

 

 

 

 

 

 

 

Recording/

Stop recording or playback.

 

 

 

 

playback operation

 

 

 

 

 

 

 

 

 

Countermeasures

Replace the affected P2 card.

 

 

 

 

 

 

 

 

 

 

 

 

97