Chapter 7 Maintenance and Inspections (continued)

7-3 Warning System

7-3-1 Warning Description Tables

If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the WARNING lamp, lamps inside the viewfinder and a warning tone.

<Note>

The WARNING lamp has the highest priority, followed by the tally lamp, and then the warning tone. When multiple errors occur simultaneously a higher priority indication will be triggered. The [WIRELESS RF], however, may not be indicated, depending on the menu setting.

1. System Errors

 

 

 

 

3. Battery Empty

 

 

 

 

 

 

 

 

 

 

 

 

 

Display window

The error code lights up.

 

 

 

 

Display window

All 7 bar indicators for

battery remaining

 

indication

 

 

 

 

indication

capacity start blinking.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING lamp

Blinks 4 times per second.

 

 

 

WARNING lamp

Lights up.

 

 

 

 

 

 

 

 

 

 

 

 

 

Tally lamp

Blinks 4 times per second.

 

 

 

Tally lamp

Blinks once per second.

 

 

7

 

 

 

 

 

 

 

 

 

 

Viewfinder

The SYSTEM ERROR

indication

and

the

 

Viewfinder

The BATT LED lights up.

 

 

error code light up.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning tone

Beeps continuously.

 

 

 

 

 

 

 

 

 

 

 

 

Warning tone

Beeps continuously.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

The battery has run out.

 

 

 

Warning

An error in the reference signal

or

the

 

 

 

 

description

 

 

 

description

communication.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recording/

The operation stops.

 

 

 

Recording/

 

 

 

 

 

 

 

The operation stops.

 

 

 

 

playback operation

 

 

 

playback operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Countermeasures

Replace the battery.

 

 

 

Countermeasures

Please confirm [7-3-2

Error Codes]

and

 

 

 

 

 

 

 

 

 

consult your distributor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Card removal error

Display window

Error code E-30 appears.

indication

 

 

 

WARNING lamp

Blinks 4 times per second.

 

 

Tally lamp

Blinks 4 times per second.

 

 

Viewfinder

The “TURN POWER OFF” indicator blinks.

 

 

Warning tone

Continues to beep.

 

 

Warning

The P2 card being accessed has been

removed, resulting in an error in the internal

description

memory of the camera-recorder.

 

 

 

Recording/

Cannot be performed.

playback operation

 

 

 

Turn off the power to the camera-recorder. If

Countermeasures

there is an error in a clip on the removed P2

 

card, repair the clip.

 

 

4. Write-protect

Display window

All 7 bar indicators for remaining MEDIA

indication

capacity start blinking.

 

 

 

 

 

 

 

 

WARNING lamp

Continues to light up until

an

operation

is

performed.

 

 

 

 

 

 

 

 

 

Tally lamp

Continues to blink 4 times per second until

an operation is performed.

 

 

 

 

 

 

 

 

 

 

 

 

Viewfinder

The WP indicator blinks.

 

 

 

 

 

 

 

 

Warning tone

Continues to beep until

an

operation

is

performed.

 

 

 

 

 

 

 

 

 

 

 

 

Warning

The inserted P2 cards are write-protected.

 

description

 

 

 

 

 

 

 

 

 

 

Recording/

Recording is disabled.

 

 

 

playback operation

 

 

 

 

 

Countermeasures

Disable the write-protect or replace the P2

card.

 

 

 

 

 

 

 

 

 

 

 

 

95