Chapter 7 Maintenance and Inspections (continued)
5. P2 Card Fully Recorded
Display window | All 7 bar indicators for remaining MEDIA | |||
indication | capacity start blinking. |
|
|
|
|
|
|
|
|
WARNING lamp | Continues to light up until | an | operation | is |
performed. |
|
|
| |
|
|
|
| |
|
| |||
Tally lamp | Continues to blink 4 times per second until | |||
an operation is performed. |
|
|
| |
|
|
|
| |
|
|
|
|
|
Viewfinder | The END indicator blinks. |
|
|
|
|
|
|
|
|
Warning tone | Continues to beep until | an | operation | is |
performed. |
|
|
| |
|
|
|
| |
|
| |||
Warning | The P2 cards are recorded to maximum | |||
description | capacity. |
|
|
|
|
|
|
|
|
Recording/ | The recording stops. |
|
|
|
playback operation |
|
|
| |
|
| |||
Countermeasures | Delete the clips in the P2 card or insert a | |||
new P2 card. |
|
|
| |
|
|
|
| |
|
|
|
|
|
7. Low Wireless Signal Reception
Display window | No display. | |
indication | ||
| ||
|
| |
WARNING lamp | Blinks 4 times per second. (During pause | |
and recording) | ||
| ||
|
| |
Tally lamp | Blinks 4 times per second while recording | |
continues. | ||
| ||
|
| |
Viewfinder | The WIRELESS RF indicator lights up while | |
recording continues. | ||
| ||
|
| |
Warning tone | Beeps 4 times per second while recording | |
continues. | ||
| ||
|
| |
Warning | This error indicates poor wireless audio | |
description | reception conditions. | |
|
| |
Recording/ | Continues to operate without receiving the | |
playback operation | wireless microphone signal. | |
|
| |
Countermeasures | Check the microphone power supply and the | |
reception status of the wireless receiver. | ||
| ||
|
|
6. Recording Error
| “00:00:00:11” appears in the time code | |
Display window | display field. Even after recording is stopped, | |
indication | this display continues to blink until the next | |
| operation is performed. | |
|
| |
WARNING lamp | Blinks 4 times per second while recording | |
continues. | ||
| ||
|
| |
Tally lamp | Blinks 4 times per second while recording | |
continues. | ||
| ||
|
| |
Viewfinder | The REC WARNING indicator lights up. | |
|
| |
Warning tone | Beeps 4 times per second while recording | |
continues. | ||
| ||
|
| |
Warning | This indicates a failure either in the P2 card | |
description | recording or the recording circuit. | |
|
| |
Recording/ | Recording stops. | |
playback operation | ||
|
| |
| Restart recording. Or, turn the power OFF | |
Countermeasures | and turn it ON again, before starting | |
| recording. | |
|
|
8. 1394 (when
Display window | The 1394 | ||
indication | window lights up. | ||
|
|
| |
WARNING lamp | Blinks | 4 times per second while the | |
WARNING lamp recording is continuing. | |||
| |||
|
| ||
WARNING lamp | Blinks 4 times per second while the TALLY | ||
LAMP recording is continuing. | |||
| |||
|
| ||
| In the case of Error Code 92, “1394 INITIAL | ||
| ERROR” indicator lights up (during pause | ||
Viewfinder | and recording) | ||
For Error Codes other than Error Code 92, or | |||
| |||
| if REC SIGNAL is set to “1394”, no error is | ||
| displayed in the viewfinder. | ||
|
|
| |
Warning tone | Beeps | 4 times per second while ALARM | |
recording is continuing. | |||
| |||
|
| ||
Warning | This indicates a failure of the DVCPRO/DV | ||
description | connector. | ||
|
| ||
Recording/ | The operation continues, but input signals to | ||
playback operation | the DVCPRO/DV connector are abnormal. | ||
|
| ||
| Check the connection between the | ||
| IEEE1394 cable and the DVCPRO/DV | ||
| connector, settings of any external device | ||
Countermeasures | and menus, and the turn on the power again. | ||
If the warning indication is still illuminated, | |||
| |||
| confirm the “Error Codes” in the IEEE1394 | ||
| interface board instruction manual, and | ||
| consult your distributor. | ||
|
|
|
96