Chapter 7 Maintenance and Inspections (continued)

5. P2 Card Fully Recorded

Display window

All 7 bar indicators for remaining MEDIA

indication

capacity start blinking.

 

 

 

 

 

 

 

 

WARNING lamp

Continues to light up until

an

operation

is

performed.

 

 

 

 

 

 

 

 

 

Tally lamp

Continues to blink 4 times per second until

an operation is performed.

 

 

 

 

 

 

 

 

 

 

 

 

Viewfinder

The END indicator blinks.

 

 

 

 

 

 

 

 

Warning tone

Continues to beep until

an

operation

is

performed.

 

 

 

 

 

 

 

 

 

Warning

The P2 cards are recorded to maximum

description

capacity.

 

 

 

 

 

 

 

 

Recording/

The recording stops.

 

 

 

playback operation

 

 

 

 

 

Countermeasures

Delete the clips in the P2 card or insert a

new P2 card.

 

 

 

 

 

 

 

 

 

 

 

 

7. Low Wireless Signal Reception

Display window

No display.

indication

 

 

 

WARNING lamp

Blinks 4 times per second. (During pause

and recording)

 

 

 

Tally lamp

Blinks 4 times per second while recording

continues.

 

 

 

Viewfinder

The WIRELESS RF indicator lights up while

recording continues.

 

 

 

Warning tone

Beeps 4 times per second while recording

continues.

 

 

 

Warning

This error indicates poor wireless audio

description

reception conditions.

 

 

Recording/

Continues to operate without receiving the

playback operation

wireless microphone signal.

 

 

Countermeasures

Check the microphone power supply and the

reception status of the wireless receiver.

 

 

 

6. Recording Error

 

“00:00:00:11” appears in the time code

Display window

display field. Even after recording is stopped,

indication

this display continues to blink until the next

 

operation is performed.

 

 

WARNING lamp

Blinks 4 times per second while recording

continues.

 

 

 

Tally lamp

Blinks 4 times per second while recording

continues.

 

 

 

Viewfinder

The REC WARNING indicator lights up.

 

 

Warning tone

Beeps 4 times per second while recording

continues.

 

 

 

Warning

This indicates a failure either in the P2 card

description

recording or the recording circuit.

 

 

Recording/

Recording stops.

playback operation

 

 

 

Restart recording. Or, turn the power OFF

Countermeasures

and turn it ON again, before starting

 

recording.

 

 

8. 1394 (when AJ-YAD800G is attached)

Display window

The 1394 E-__indicator in the display

indication

window lights up.

 

 

 

WARNING lamp

Blinks

4 times per second while the

WARNING lamp recording is continuing.

 

 

 

WARNING lamp

Blinks 4 times per second while the TALLY

LAMP recording is continuing.

 

 

 

 

In the case of Error Code 92, “1394 INITIAL

 

ERROR” indicator lights up (during pause

Viewfinder

and recording)

For Error Codes other than Error Code 92, or

 

 

if REC SIGNAL is set to “1394”, no error is

 

displayed in the viewfinder.

 

 

 

Warning tone

Beeps

4 times per second while ALARM

recording is continuing.

 

 

 

Warning

This indicates a failure of the DVCPRO/DV

description

connector.

 

 

Recording/

The operation continues, but input signals to

playback operation

the DVCPRO/DV connector are abnormal.

 

 

 

Check the connection between the

 

IEEE1394 cable and the DVCPRO/DV

 

connector, settings of any external device

Countermeasures

and menus, and the turn on the power again.

If the warning indication is still illuminated,

 

 

confirm the “Error Codes” in the IEEE1394

 

interface board instruction manual, and

 

consult your distributor.

 

 

 

96