Chapter 5 Preparation (continued)

When using a BP-90 type battery pack

CAUTION:

These servicing instructions are for use by qualified service personnel only. To reduce the risk of fire or electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

1Remove the battery holder.

Battery holder

2Attaching the battery case to the camera-recorder. Connect the cable on the camera-recorder to the cable on the battery case (BP-90 type).

Using a screwdriver, secure the battery case (BP-90 type) to the camera-recorder.

Open the cover and lift the rubber cap so that the screw tightening hole is visible. Tighten the screws to secure the battery case to the camera-recorder. Be sure to fully tighten the screws.

3Connect the battery pack plug to the socket inside the battery case, and insert the battery pack into the case.

5

Label surface

<Note>

Make sure you turn OFF the camera-recorder power before connecting or disconnecting the plug.

4Setting the battery type.

Select the battery type listed under BATTERY SELECT. Select BATTERY SELECT from the <BATTERY/ P2CARD> screen on the MAIN OPERATION page.

Please refer to [8-6-2 BATTERY SETTING1] for more information.

<Notes>

zDo not use excess force when lifting the rubber caps forcibly.

zTake special care not to pinch the cable.

Connect

Battery Case (For BP-90 type)

65