Paradyne 2 of 3800 Series S-Registers, Description, Front Panel Branch, Line Feed Character

Models: 3800

1 213
Download 213 pages 48.38 Kb
Page 157
Image 157
(2 of 12)

COMSPHERE 3800 Series Modems

S-Register

Table 14-2

(2 of 12)

3800 Series S-Registers

Description

Front Panel Branch

 

 

S4

Line Feed Character

Configure\Edit\DTE Dialer

 

Register determines ASCII value used as the line feed character.

 

 

Enter a value from 0 to 127 for the line feed character.

 

 

Factory setting is 10 (ASCII carriage return or line feed).

 

 

 

 

S5

Backspace Character

Configure\Edit\DTE Dialer

 

Register determines ASCII value used as the backspace (Backspace

 

 

key). This character moves the cursor to the left and erases the previous

 

 

character.

 

 

Enter a value from 0 to 127.

 

 

Factory setting is 08 (backspace key).

 

 

 

 

S6

Blind Dial Pause

Configure\Edit\Line Dialer

 

Register determines how long (in seconds) the modem waits after going

 

 

off-hook before dialing a telephone number if using result code X0, X1,

 

 

or X3.

 

 

Enter a value from 2 to 255 seconds.

 

 

Factory setting is 2 seconds.

 

 

 

 

S7

No Answer Timeout

Configure\Edit\Line Dialer

 

Register determines how long (in seconds) an originating modem waits

 

 

before abandoning a call when no answer tone is received.

 

 

Enter a value from 1 to 255 seconds.

 

 

Factory setting is 45 seconds.

 

 

 

 

S8

‘‘,” Pause Time for the Dial Modifier

Configure\Edit\Line Dialer

 

Register determines how long (in seconds) the modem pauses when it

 

 

encounters a comma (,) in the Dial command string.

 

 

Enter a value from 0 to 255 seconds.

 

 

Factory setting is 2 seconds.

 

 

 

 

S10

No Carrier Disconnect

Configure\Edit\Line Dialer

 

Register determines how long (in tenths of seconds) the modem allows

 

 

the carrier signal to be off before disconnecting the call.

 

 

Enter a value from 0 to 254 in 0.1 second increments. (A value of 255

 

 

disables this register.)

 

 

Factory setting is 20 (2 seconds).

 

 

 

 

S12

Escape Guard Time

Configure\Edit\DTE Dialer

 

Register sets the value (in 20-millisecond increments) for the required

 

 

pause before and after the escape sequence is issued. The guard time

 

 

prevents the modem from interpreting data as the escape sequence

 

 

characters.

 

 

Enter a value from 0 to 255 in 20-millisecond increments. For example,

 

 

the factory setting of 50 equals 1000 milliseconds or one second.

 

 

Factory setting is 50 (1 second).

 

 

 

 