COMSPHERE 3800 Series Modems

S-Register

Table 14-2

(4 of 12)

3800 Series S-Registers

Description

Front Panel Branch

 

 

S36

Rate Auto Originate

Initiates a dial backup call, using the phone number in directory

location 1, when the leased-line rate of the modem falls back to or below a certain speed.

Register has the following values:

S36 = 0 Disable

S36 = 1 On fallback to 4800

S36 = 2 On fallback to 7200

S36 = 3 On fallback to 9600

S36 = 4 On fallback to 12,000

S36 = 5 On fallback to 14,400

S36 = 6 On fallback to 16,800

NOTE: Rate Auto-Originate is valid only when V.32bis Autorate is enabled (S76 = 0).

Configure\Edit\Leased Line

S37

Auto Redial (DTR)

 

Configure\Edit\Line_Dialer

 

Auto Redial allows repeated automatic dial backup attempts by

(DTR Auto Redial)

 

specifying the range of Directory Locations that can be tried. A redial

 

 

attempt is made in response to a bad phone number, a busy signal, no

 

 

answer, or no quiet answer. The modem must be in Originate mode.

 

 

When DTE Dialer Type is DTR=Dirs, Auto Redial works in conjunction

 

 

with the DTR Cont Repeat (S38) configuration option.

 

 

Register has the following values:

 

 

S37 = 0 Use Directory Location 1

 

 

S37 = 1 Use Directory Locations 1–2

 

 

S37 = 2 Use Directory Locations 1–3

 

 

S37 = 3 Use Directory Locations 1–4

 

 

S

S

S

 

 

S

S

S

 

 

S37 = 9 Use Directory Locations 1–10

 

 

NOTE: The modem must be in Originate mode to perform an automatic

 

 

dial backup.

 

 

 

 

 

 

S38

DTR Cont Repeat

 

Configure\Edit\DTE_Dialer

 

Determines whether automatic dialing of dial backup directory locations

 

 

will be repeated continuously, or halted after the first pass.

 

 

Regardless of the setting of S38, dialing is locked out after ten failed

 

 

attempts to connect to the same number.

 

 

Register has the following values:

 

 

0 = Disable

 

 

 

 

1 = Enable

 

 

 

 

Factory setting is Disable.

 

 

 

 

 

 

 