Paradyne 3800 manual 01 9W5556789 z, Valid Dial Command Modifiers, AT Command Equivalent

Models: 3800

1 213
Download 213 pages 48.38 Kb
Page 53
Image 53
01 : 9W5556789 z

COMSPHERE 3800 Series Modems

01 : 9W5556789 z

Nxt￿￿￿￿" #

F1 F2 F3

To save the number just entered, scroll to the next directory location by selecting Nxt or press the " or # key. The number is now stored in nonvolatile memory.

AT Command Equivalent

The AT command for Change Directory is & Zn=x, where n is the directory location and x is the telephone number.

Table 5-1 describes what can be entered in directory locations.

Table 5-1

Valid Dial Command Modifiers

Dial Command modifiers are parameters entered in the dial command string which specify how, when, and what number to dial. The following is a list of parameters the 3800 Series Modems recognize:

T – Tone (DTMF) dial. Any digit 0–9, *, #, A, B, C, or D can be dialed as tone.

P – Pulse dial. Only the digits 0–9 can be dialed in Pulse Dial mode.

Once a dialing method (tone or pulse) has been specified, it will only remain active until the end of that dial string. The modem defaults to the value set by the Dialer Type configuration option.

,– Pause. Causes the modem to pause before processing the next character in the dial string. The length of this pause is determined by the setting of the Pause Time configuration option (see Line Dialer configuration option group) or by value held in S-register S8.

W or + – Wait for dial tone. Modem waits for a second dial tone before processing the dial string. This can be the initial dial tone or can be used when dialing through a tandem PBX. For example, 9W 555-6789.

R – Reverse Dial mode. Causes the originating modem to send out an answertone once it no longer detects ringback. (Ringback is the ring you hear at the originating site when making a call.) The R parameter must be the last character in the dial string.

@– Quiet answer. Wait for five seconds of silence after dialing the number. If the silence is not detected, the modem sends the NO ANSWER result code to the DTE or displays the No Quiet Answer LCD status message.

!– Hook flash. This causes the modem to go on-hook for 0.5 seconds then return to off-hook.

;– Return to Command mode. Modem returns to Command mode after dialing a number without disconnecting the call. This permits you to enter long international telephone numbers, or additional information such as a calling card number, that would exceed the 40-character limit.

Space, –, and ( ). These characters are ignored by the dial string and can be included to enhance readability.

zEnd of Number. Hides all characters appearing on the LCD entered to the right of this indicator.