Configure Branch

Table 9-3

(2 of 5)

Line Dialer Configuration Options

Blind Dial Paus: 2sec

Nxt 2sec 4sec 6sec 8sec 10sec 20sec

Blind Dial Pause. Determines how long the modem waits before dialing a telephone number when DialTone Detect is disabled.

NOTE: The Blind Dial Pause configuration option only appears when the Dial Tone Detect configuration option is disabled.

The factory default is 2sec.

AT command is S-register S6 = n, where n is a value from 2 to 255 in 1-second increments.

BusyTone Detect: Enable

Nxt Enable Disable

Busy Tone Detect. Sets the modem to monitor for Busy Tone (Enable) or ignore Busy Tone (Disable).

This configuration option is normally enabled; however, if the modem receives false busy tones, this configuration option can be disabled and the modem ignores all busy tones.

The factory default is Enable.

AT commands to disable are X0, X1, and X2.

AT commands to enable are X3, X4, X5, X6, and X7.

‘‘,” Pause Time: 2sec

Nxt 2sec 4sec 6sec 8sec 10sec 20sec

Pause Time. Determines the number of seconds the modem pauses when it encounters a comma (,) in the dial command string.

NOTE: Although DCP selections are limited (2, 4, 6, 8, 10, or 20), values set by the AT commands can display from 0 to 255 seconds.

The factory default is 2sec.

AT command is S-register S8 = n, where n is a value from 0 to 255 in 1-second increments.

NoAnswer Timout: 45sec

Nxt 45sec 30sec 60sec 120sec

No Answer Abort Time-out. Determines the number of seconds an originating modem waits before abandoning a call attempt when no answer tone is received.

NOTE: Although DCP selections are limited (30, 45, 60, or 120), values set by AT commands can display from 1 to 255 seconds.

The factory default is 45sec.

AT command for No Answer Timeout is S-register S7 = n, where n is a value from 1 to 255 in 1-second increments.