AT Command Set and S-Registers

S-Register

Table 14-2

(11 of 12)

3800 Series S-Registers

Description

Front Panel Branch

 

 

S81

2W Leased Line SQ Retrain

Configure\Edit\Leased Line

 

Forces the modem to retrain if the SQ (Signal Quality) LED is on for

 

 

more than the specified number of seconds (1–5). 2W SQ Retrain

 

 

reduces the amount of bad data sent to the DTE when no error control is

 

 

used, but greatly increases the likelihood of retrains on impaired lines.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1–5 = Retrain is initiated after this number of seconds of SQ problems

 

 

Factory setting is Disable.

 

 

 

 

S82

V.32bis Autorate (Leased Line)

Configure\Edit\Leased Line

 

Register determines if Autorating is used on leased lines when

 

 

connected in V.32bis mode.

 

 

Register has the following values:

 

 

0

= Enable

 

 

1

= Disable

 

 

Factory setting is Enable.

 

 

 

 

S84

AT Command Mode

Configure\Edit\DTE Dialer

 

Register determines how the modem responds to valid and invalid AT

 

 

commands.

 

 

Register has the following values:

 

 

0

= Normal

 

 

1

= No ERROR

 

 

2

= No Strap or ERROR

 

 

Factory setting is Normal.

 

 

 

 

S85

Fast Disconnect

Configure\Edit\Line Dialer

 

Register allows the modem to disconnect immediately after receiving a

 

 

disconnect command from a local DTE or its own diagnostic control

 

 

panel.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

Factory setting is Disable.

 

 

 

 

S88

Straps When Disconnected

Configure\Edit\V.42/MNP/

 

Register determines whether the Active(Operating) area is reloaded

Buffer

 

upon a disconnect.

 

 

Register has the following values:

 

 

0

(or 231) = No Change

 

 

1

(or 232) = Reload

 

 

2

(or 233) = Reload with no AT Change

 

 

Factory setting is No Change.

 

 

 

 

 