9 • Diagnostics | Model 3086 G.SHDSL Integrated Access Device User Guide |
|
|
BIT Error Rate (V.52) Diagnostics
The Model 3086 offers a V.52 Bit Error Rate (BER) 511 test pattern. This test pattern may be invoked along with the LAL and RDL tests to evaluate the unit(s) and the DSL communication links. When a 511 test is invoked, the 3086 generates a
If the received bits match the agreed upon
To perform a V.52 BER test, follow these steps:
1.Locate the toggle switch group on the right side on the front panel and place it in the middle where it is marked “Normal”. This activates the V.52 transmission and reception of the selected test pattern. If there are errors in the received pattern, the error LED will blink accordingly.
2.If the above test indicates no errors are present, move the toggle switch UP to 511/E, activating the BER test with intentional errors. If the test light is working properly, the local modem’s red error LED will blink approximately once per second.
Note The above V.52 BER tests can be used independently of the Remote
Digital Loopback tests.
142 | BIT Error Rate (V.52) Diagnostics |