Patton electronic manual Model 3086 Remote Configuration Steps RFC 1483 Bridged

Models: 3086

1 196
Download 196 pages 1.92 Kb
Page 74
Image 74

4 • Basic Application Configurations

Model 3086 G.SHDSL Integrated Access Device User Guide

 

 

Model 3086 (Remote) Configuration Steps (RFC 1483 Bridged)

From the command line interface (CLI) via the RS-232 control port,

ip list interfaces

One IP interface is called ip1 with an IP address of 192.168.1.1

Change the IP address so it is in the same subnet as both PCs. For example, to 192.168.100.2

ip set interface ip1 ipaddress 192.168.100.2 255.255.255.0

1.Now you can bring up the web-page management system on your browser by entering the IP address of the 3086.

2.On the Menu, go to Configuration, then to WAN Connections. Delete the factory default WAN services already defined.

Click on Create a new service in the main window, select RFC_1483_Bridged and click on the Configure button.

In the Description field, enter the description you wish. In this example, it is called RFC 1483 B. Leave VCI as 35 and Encapsulation Method as LLC/SNAP. Then click on Apply.

3.Go to G.SHDSL in the Configuration Menu, then the submenu Configuration.

74

DSLAM Connections with remote CPE units

Page 74
Image 74
Patton electronic manual Model 3086 Remote Configuration Steps RFC 1483 Bridged