4 • Basic Application Configurations | Model 3086 G.SHDSL Integrated Access Device User Guide |
|
|
Change Terminal Type to Central and Interface Type to hdlc. Click on the Configure button. In the Action submenu under G.SHDSL, change Action to Deactivate, then click on Action. Return to Action, select Start and click on Action.
Model 3086 (Central) Configuration Steps (PPPoH Bridged)
See the Web page images for the Remote Model 3086 configuration above.
From the command line interface (CLI) via the
fiip list interfaces
One IP interface is called ip1 with an IP address of 192.168.1.1
Change the IP address so it is in the same subnet as both PCs. For example, to 192.168.100.3
fiip set interface ip1 ipaddress 192.168.100.3 255.255.255.0
1.Now you can bring up the
2.On the Menu, go to Configuration, then to WAN Connections. Delete the factory default WAN services already defined.
Click on Create a new service in the main window, select PPPoH_Bridged and click on the Configure button. In the Description field, enter the description you wish. In this example, it is called PPPoH Bridged. Verify the settings to be:
–Interface = 1
–LLC header mode = dialout
66 | Using the 3086 in Routed or Bridged applications |