Model 3086 G.SHDSL Integrated Access Device User Guide

4 • Basic Application Configurations

 

 

Switch Bank S3

The table below shows the default configuration for switch S3. A description of S3 options follows this table.

Table 7. S3 Summary Table

Switch Position

Function

Factory Default

Selected Option

 

 

 

 

S3-1

CO/CP Selection

On

CO

S3-2

Reserved

On

Reserved

 

 

 

 

S3-3

Clock

On

Network

S3-4

Reserved

On

Reserved

 

 

 

 

S3-5

Reserved

On

Reserved

S3-6

Annex

Off = Annex A

Annex B

 

 

On = Annex B

 

 

 

 

 

S3-7

Reserved

On

Reserved

S3-8

Reserved

On

Reserved

 

 

 

 

Switch S3-1: CO/CP selection. CO and CP stand for Central Office and Customer Premise respectively. When deploying the model 3086s, units installed at the Customer location should be set to CP and units installed at a Central Office should be set to CO. For point-to-point operation, one unit must be CO while the other must be CP.

S3-3

Setting

 

 

Off

CP

ON

CO

 

 

Switch S3-3: Transmit Clock Mode. Use Switches S3-3 to configure the 3086 for internal or external (net- work) clock mode.

S3-3

Clock mode

 

 

Off

Internal. DSL and T1 transmit clock generated by the 3086

On

External. DSL and T1 transmit clock derived from the received T1 signal (CO con-

 

figuration only)

 

 

T1 Interface