F • Interworking Functions Information

Model 3086 G.SHDSL Integrated Access Device User Guide

 

 

933A_Network: The ITU Q.933 protocol will be used. The unit will operate as the Network side of the connection

933A_User: The ITU Q.933 protocol will be used. The unit will operate as the User side of the connection

933A_Both: The ITU Q.933 protocol will be used. The unit will operate as both the Network and User side of the connection.

617D_Network: The ANSI T1.617 protocol will be used. The unit will operate as the Network side of the connection

617D_User: The ANSI T1.617 protocol will be used. The unit will operate as the User side of the connection

617D_Both: The ANSI T1.617 protocol will be used. The unit will operate as both the Network and User side of the connection.

MgtState

Defines the current state of the DTE side LMI. Possible options are as follows:

Mgt_Port_DOWN: Currently the LMI on the DTE side is DOWN

Mgt_Port_UP: Currently the LMI on the DTE side is UP

mgtAutoStart: (Default Value: FALSE)

The management Auto Start variable allows the user to start the LMI session before any DLCI connections are created within the unit. If this variable is set to FALSE, the LMI session will begin when the first DLCI channel is created. If this variable is set to TRUE the LMI session will begin immediately.

T391_Value: (Default Value: 10)

This variable sets the T391 timers in seconds.

T392_Value: (Default Value: 16)

This variable sets the T392 timers in seconds.

fullReportCycle: (Default Value: 6)

This variable represents the N391 protocol value

netErrorWindowSize: (Default Value: 4) Network side N393 protocol value

netMaxErrors: (Default Value: 3)

Network side N392 protocol value

userErrorWindowSize: (Default Value: 4) User side N393 protocol value

userMaxErrors: (Default Value: 3) Network side N392 protocol value