4 • Basic Application Configurations

Model 3086 G.SHDSL Integrated Access Device User Guide

 

 

Switch Bank S2

Table 4 shows the default configuration for switch S2. A description of S2 options follows the table.

Table 4. S2 Summary Table

Switch Position

Function

Factory Default

Selected Option

 

 

 

 

S2-1

Serial Rate

On

Not a valid rate

S2-2

 

On

 

 

 

 

 

S2-3

 

On

 

S2-4

 

On

 

 

 

 

 

S2-5

 

On

 

S2-6

 

On

 

 

 

 

 

S2-7

 

On

 

S2-8

Switch configuration

On

Toggle On->Off>On

To activate DIP configuration

Switches S2-1 through S2-7.Use Switches S2-1 through S2-7 to set the data rate. Each position represents nx64 settings.

S7

S6

S5

S4

S3

S2

S1

Data Rate (kbps)

 

 

 

 

 

 

 

 

On

On

On

On

On

On

Off

64

On

On

On

On

On

Off

On

128

 

 

 

 

 

 

 

 

On

On

On

On

On

Off

Off

192

On

On

On

On

Off

On

On

256

 

 

 

 

 

 

 

 

On

On

On

On

Off

On

Off

320

On

On

On

On

Off

Off

On

384

 

 

 

 

 

 

 

 

On

On

On

On

Off

Off

Off

448

On

On

On

Off

On

On

On

512

 

 

 

 

 

 

 

 

On

On

On

Off

On

On

Off

576

On

On

On

Off

On

Off

On

640

 

 

 

 

 

 

 

 

On

On

On

Off

On

Off

Off

704

On

On

On

Off

Off

On

On

768

 

 

 

 

 

 

 

 

On

On

On

Off

Off

On

Off

832

On

On

On

Off

Off

Off

On

896

 

 

 

 

 

 

 

 

On

On

On

Off

Off

Off

Off

960

On

On

Off

On

On

On

On

1024

 

 

 

 

 

 

 

 

On

On

Off

On

On

On

Off

1088

On

On

Off

On

On

Off

On

1152

 

 

 

 

 

 

 

 

On

On

Off

On

On

Off

Off

1216

On

On

Off

On

Off

On

On

1280

 

 

 

 

 

 

 

 

On

On

Off

On

Off

On

Off

1344

On

On

Off

On

Off

Off

On

1408

 

 

 

 

 

 

 

 

42

V.35 and X.21 Ports

Page 42
Image 42