Serial Port Profiles

Email Alert Tab Field Descriptions

Email notification can be set at the Server and/or serial port levels. You can set unique email notifications for each serial port because the person who administers the IOLAN might not be the same person who administers the serial device(s) attached to the IOLAN port. Therefore, email notification can be sent to the proper person(s) responsible for the hardware.

The following event triggers an email notification on the Serial Port for the specified Level:

zDSR signal loss, Warning Level

zI/O alerts, Critical Level

Configure the following parameters:

Enable Port Email

Enable/disable email alert settings for this serial port.

Alert

Default: Disabled

Use System Email

Determines whether you want the Serial Port to inherit the Email Alert settings

Alert Settings

from the System Email Alert configuration. If this is enabled, System and

 

Serial Port notification events will have the same Email Alert setting.

 

Default: Enabled

Level

Choose the event level that triggers an email notification.

 

Data Options: Emergency, Alert, Critical, Error, Warning, Notice, Info,

 

Debug

 

Default: Emergency

To

An email address or list of email addresses that will receive the email

 

notification.

Subject

A text string, which can contain spaces, that will display in the Subject field of

 

the email notification.

From

This field can contain an email address that might identify the IOLAN name or

 

some other value.

Reply To

The email address to whom all replies to the email notification should go.

Outgoing Mail

The SMTP host (email server) that will process the email notification request.

Server (SMTP)

This can be either a host name defined in the IOLAN host table or the SMTP

 

host IP address.

119

Page 119
Image 119
Perle Systems 5500161-40 manual Email Alert Tab Field Descriptions