Powering Up the IOLAN

Wiring up a DHV unit

 

Terminal #

Description

Usage

 

 

 

 

 

1

Normally Open

Normally Open is a fail-safe relay connection. Use this with the

 

 

 

Common terminal to act as switch contacts that remain open when

 

 

 

the unit is powered off or in a failure state.

 

 

 

 

 

2

Common

Common is a fail-safe relay connection. Use this terminal in

 

 

 

conjunction with the Normally Open or Normally Closed terminals.

 

 

 

 

 

3

Normally

Normally Closed is a fail-safe relay connection. Use this with the

 

 

Closed

Common terminal to act as switch contacts that remain closed

 

 

 

when the unit is powered off or in a failure state.

 

 

 

 

 

4

Chassis Ground

Chassis Ground must be connected to "Equipment Ground" for DC

 

 

 

installations or "Safety Ground" for AC installations.

 

 

 

 

 

5

+ / L (source 1)

+ / L (Source 1) is connected to the positive (+) input for DC

 

 

 

sources or to the Live input for AC sources. Use with partner

 

 

 

terminal -/N(Source 1).

 

 

 

 

 

6

- / N(source 1)

- / N (Source 1) is connected to the negative (-) input for DC

 

 

 

sources or to the Neutral input for AC sources. Use with partner

 

 

 

terminal +/L(Source 1).

 

 

 

 

 

7

+ / L (source 2)

+ / L (Source 2) is connected to the positive (+) input for DC

 

 

 

sources or to the Live input for AC sources. Use with partner

 

 

 

terminal -/N(Source 2).

 

 

 

 

 

8

- / N(source 2)

- / N (Source 2) is connected to the negative (-) input for DC

 

 

 

sources or to the Neutral input for AC sources. Use with partner

 

 

 

terminal +/L(Source 2).

 

 

 

 

 

E

Earth Ground

Earth Ground is a connection to the chassis that can be used for

 

 

 

earth bonding.

 

 

 

 