Voltage

Minimum tolerance = -38VDC

Nominal rating = -48 to -60VDC

Maximum tolerance = -75VDS

Maximum input current = 17.0 Amps

The power supply will power-off if the DC input is less than -34 VDC.

DC Power Supply LED Indicators

Power Supply condition

Power Supply LED

 

 

No DC power to all PSUs

Off

 

 

No DC power to this PSU only

Amber

 

 

DC present/Only Standby Outputs On

Blink Green

 

 

Power supply DC outputs ON and OK

Green

 

 

Current limit

Amber

 

 

Power supply failure

Amber

 

 

AC Power Supply Interface Requirements

The AC power supply operates within the following limits:

AC line voltage = Auto-ranging for either 100-127 VAC or 200-240 VAC

AC line frequency = 50/60 Hz

AC input current = 4 Amp at 100-127 VAC, 2 Amp at 200-240 VAC

AC Power Supply LED Indicators

Power Supply condition

Power Supply LED

 

 

No AC power to all PSUs

Off

 

 

No AC power to this PSU only

Amber

 

 

DC present/Only Standby Outputs On

Blink Green

 

 

Power supply DC outputs ON and OK

Green

 

 

Power supply in Alert Condition

Blink Amber

 

 

Power supply failure

Amber

 

 