User Guide V2IU 6400-S Converged Network Appliance
Voltage
•Minimum tolerance =
•Nominal rating =
•Maximum tolerance =
•Maximum input current = 17.0 Amps
The power supply will
DC Power Supply LED Indicators
Power Supply condition | Power Supply LED |
|
|
No DC power to all PSUs | Off |
|
|
No DC power to this PSU only | Amber |
|
|
DC present/Only Standby Outputs On | Blink Green |
|
|
Power supply DC outputs ON and OK | Green |
|
|
Current limit | Amber |
|
|
Power supply failure | Amber |
|
|
AC Power Supply Interface Requirements
The AC power supply operates within the following limits:
•AC line voltage =
•AC line frequency = 50/60 Hz
•AC input current = 4 Amp at
AC Power Supply LED Indicators
Power Supply condition | Power Supply LED |
|
|
No AC power to all PSUs | Off |
|
|
No AC power to this PSU only | Amber |
|
|
DC present/Only Standby Outputs On | Blink Green |
|
|
Power supply DC outputs ON and OK | Green |
|
|
Power supply in Alert Condition | Blink Amber |
|
|
Power supply failure | Amber |
|
|
2 - 4