Attribute

Permitted

Interpretation

Values

 

 

 

ind.gi.x.y.class

positive integer

Assigns the class (defined above) for this indicator.

 

 

 

ind.gi.x.y.physX

IP 300: 0-19

For GraphicIcon type indicators, this is the x-axis loca-

 

IP 500: 0-159

tion of the upper left corner of the indictor measured in

 

pixels from left to right.

 

IP 600: 0-319

 

 

 

IP 4000: 0-247

 

 

 

 

ind.gi.x.y.physY

IP 300: 0-3

For GraphicIcon type indicators, this is the y-axis loca-

 

IP 500: 0-79

tion of the upper left corner of the indicator measured in

 

pixels from top to bottom.

 

IP 600: 0-159

 

 

 

IP 4000: 0-67

 

 

 

 

ind.gi.x.y.physW

IP 300: n/a

For GraphicIcon type indicators, this is the width of the

 

IP 500: 1-160

indicator measured in pixels.

 

 

 

IP 600: 1-320

 

 

IP 4000: 1-248

 

 

 

 

ind.gi.x.y.physH

IP 300: n/a

For GraphicIcon type indicators, this is the height of the

 

IP 500: 1-80

indicator measured in pixels.

 

 

 

IP 600: 1-160

 

 

IP 4000: 1-68

 

 

 

 

4.6.1.16 Event Logging <logging/>

Warning!

Logging parameter changes can impair system operation. Do not change any logging parameters

without prior consultation with Polycom.

 

 

 

The event logging system supports the following classes of events:

Level

Interpretation

 

 

0

Debug only

 

 

1

High detail event class

 

 

2

Moderate detail event class

 

 

3

Low detail event class

 

 