Administrator Guide - SoundPoint® IP / SoundStation® IP

Optimization

4.6.1.7.2.2 Call Control <CallControl/>

These parameters apply to call control packets, such as the network protocol signaling.

Attribute

Permitted

Default

Interpretation

Values

 

 

 

 

qos.ip.callControl.min_delay

0, 1

1

If set to 1, set min-delay bit in

 

 

 

the IP TOS field of the IP

 

 

 

header, or else don’t set it.

 

 

 

 

qos.ip.callControl.max_throughput

0, 1

0

If set to 1, set max-throughput

 

 

 

bit in the IP TOS field of the IP

 

 

 

header, or else don’t set it.

 

 

 

 

qos.ip.callControl.max_reliability

0, 1

0

If set to 1, set max-reliability bit

 

 

 

in the IP TOS field of the IP

 

 

 

header, or else don’t set it.

 

 

 

 

qos.ip.callControl.min_cost

0, 1

0

If set to 1, set min-cost bit in the

 

 

 

IP TOS field of the IP header, or

 

 

 

else don’t set it.

 

 

 

 

qos.ip.callControl.precedence

0-7

5

If set to 1, set precedence bits in

 

 

 

the IP TOS field of the IP

 

 

 

header, or else don’t set them.

 

 

 

 

4.6.1.8 Basic TCP/IP <TCP_IP/>

4.6.1.8.1 Network Monitoring <netMon/>

Do not alter these values.

Attribute

Permitted Values

Default

 

 

 

tcpIpApp.netMon.enabled

0, 1

1

 

 

 

tcpIpApp.netMon.period

1 to 86400

30

 

 

 

4.6.1.8.2 Time Synchronization <SNTP/>

The following table describes the parameters used to set up time synchronization and daylight savings time. The defaults shown will enable daylight savings time for North America.

Daylight savings defaults:

don’t use fixed day, use first or last day of week in the month,

start DST on the first Sunday in April at 2 am,