Administrator Guide - SoundPoint® IP / SoundStation® IP Optimization
88 Copyright © 2004 Polycom, Inc.
4.6.1.7.2.2 Call Control <CallControl/>

These parameters apply to call control packets, such as the network protocol signaling.

4.6.1.8 Basic TCP/IP <TCP_IP/>

4.6.1.8.1 Network Monitoring <netMon/>

Do not alter these values.

4.6.1.8.2 Time Synchronization <SNTP/>

The following table describes the parameters used to set up time synchronization and

daylight savings time. The defaults shown will enable daylight savings time for

North America.

Daylight savings defaults:

• don’t use fixed day, use first or last day of week in the month,
• start DST on the first Sunday in April at 2 am,
Attribute
Permitted
Values Default Interpretation
qos.ip.callControl.min_delay 0, 1 1 If set to 1, set min-delay bit in
the IP TOS field of the IP
header, or else don’t set it.
qos.ip.callControl.max_throughput 0, 1 0 If set to 1, set max-throughput
bit in the IP TOS field of the IP
header, or else don’t set it.
qos.ip.callControl.max_reliability 0, 1 0 If set to 1, set max-reliability bit
in the IP TOS field of the IP
header, or else don’t set it.
qos.ip.callControl.min_cost 0, 1 0 If set to 1, set min-cost bit in the
IP TOS field of the IP header, or
else don’t set it.
qos.ip.callControl.precedence 0-7 5 If set to 1, set precedence bits in
the IP TOS field of the IP
header, or else don’t set them.
Attribute Permitted Values Default
tcpIpApp.netMon.enabled 0, 1 1
tcpIpApp.netMon.period 1 to 86400 30