Polycom Version 1.4.x 17 manual Basic Logging level/change/ and render, Type Example

Models: Version 1.4.x 17

1 147
Download 147 pages 13.75 Kb
Page 112
Image 112

Administrator Guide - SoundPoint® IP / SoundStation® IPOptimization

Level

Interpretation

 

 

4

Minor error - graceful recovery

 

 

5

Major error - will eventually incapacitate the system

 

 

6

Fatal error

 

 

Each event in the log contains the following fields separated by the character:

time or time/date stamp

1-5 character component identifier (such as “so”)

event class

cumulative log events missed due to excessive CPU load

free form text - the event description

Example:

011511.006so 200soCoreAudioTermChg: chassis -> idle

time stamp

ID

event class missed events text

Three formats are available for the event timestamp:

Type

Example

 

 

 

 

 

0

- seconds.milliseconds

011511.006

-- 1 hour, 15 minutes, 11.006 seconds

 

 

since booting.

 

 

 

 

 

1

- absolute time with minute resolution

0210281716

-- 2002 October 28, 17:16

2

- absolute time with seconds resolution

1028171642

-- October 28, 17:16:42

4.6.1.16.1 Basic Logging <level/><change/> and <render/>

Attribute

Permitted

Default

Interpretation

Values

 

 

 

 

log.level.change.xxx

0-5

4

Control the logging detail level

 

 

 

for individual components.

 

 

 

These are the input filters into

 

 

 

the internal memory-based log

 

 

 

system.

 

 

 

 

104