UPCSHIP
201
d. The information for the data field is entered
dynamically during the Execute Form Mode.
(Refer to “Execute Form: Dynamic Bar Code
Data” on page 63.) Do not use the
data field
parameter to enter data when the BF
n
parameters are used. However, refer to the
data field
description for available characters.
DARK Optional parameter to produce darker looking bar
codes. Enter DARK. Refer to “Dark Printing” on
page 28 for more information.
SR
Defines the starting row for the bar code. Enter a
value ranging from row 1 to one less than the
length of the form. Character row or dot row is
specified based on the Scale command (page 89),
or use the CP.DP format (page 26).
SC
Defines the starting column of the bar code. Enter a
value ranging from column 1 to one less than the
width of the form. Character column or do t column
is specified based on the Scale command (page
89), or use the CP.DP format (page 26).
(D)
The printable character (delimiter) identifying the
start and finish of the data field. Enter any printable
character other than a slash (/), the SFCC, or a
character used within the data. The same character
must be used at both ends of the data field, but it
will not print with the data.
data field
The barcode data. The UPCSHIP barcode requires
exactly 13 characters of data. The available
characters are 0 through 9 (hex 30 through hex 39).
The modulo-10 check digit is automatically included
in the barcode.
PDF Optional parameter to enable printing of the human
readable data field. Enter PDF to print the data
field. If the parameter is not used, the human
readable data is not printed.
LOC
Optional parameter to identify the location of the
printable data field. The default value is B, locating
the human readable data below the bar code. A
locates the printable data field above bar code. To
compensate for printing the 0.1-inch high data, the
height of the bar code body is reduced 0.1-inch.