Incremental Bar Code Fixed Data Fields

Incremental Bar Code Fixed Data Fields

The Incremental Bar Code Fixed Data Fields command is a variation of the standard IGP bar code commands. Use this command with the appropriate parameters from the standard bar code command when automatic incrementing of fixed bar code data fields is required. The Incremental Bar Code Fixed Data Fields command format is shown and defined below. (Incremental command parameters are shown in boldface type; standard bar code command parameters and optional nonincremental parameters are shown in italics.)

BARCODE

type; [VSCAN;] [MAG;] [Hn;] I; [DARK;] SR; SC

[idir] STEPMASK; [RPTn;] [RSTn;] (D)STARTDATA(D) [PDF [;LOC] [;FONT]]

STOP

IIdentifies this bar code command as an Incremental Bar Code command; enter I.

idir

The optional increment direction parameter to

 

specify an increment (add) or decrement (subtract)

 

to the data. Enter a plus sign (+) or leave the field

 

blank to increment (the default). Enter a minus sign

 

(-) to decrement.

STEPMASK Defines the increment amount (step), number of character positions in the data field, and provides a mask to control the increment function on specific parts of the data. Refer to “Incrementing Bar Code Data” on page 208 for complete information on STEPMASK parameter values.

RPTn

The optional incremental repeat count parameter to

 

specify the number of times a particular field value

 

will repeat before it is incremented. A repeated field

 

value is useful when printing multiple rows/columns

 

of identical labels before increasing to the next

 

value. To use the repeat count parameter, enter

 

RPT and replace n with a numeric value ranging

 

from 1 through 65,535 to specify the repeat count.

 

The default repeat count parameter is 1, which will

 

increment the field value each time it is printed.

RSTn

The optional incremental reset count parameter to

 

specify the number of times an incremented field is

 

printed (on one or more forms) before it is reset to

 

the starting value. A reset count is useful when

 

printing a hierarchy of fields where a low-level field

 

generates a sequence of numbers, is reset, and the

 

next higher field level is incremented (such as in a

 

unit/box/carton application). To use the reset count

 

parameter, enter RST and replace n with a number

 

ranging from 1 through 65,535 to specify the reset

 

count. The default reset count value is 0.

211