Chapter 6 IGP/PGL Emulation Error Codes

123EXECUTE form too long for current page setting

The form was defined in one orientation while sent to print in another orientation. Use the debug slash (/) when creating a form to show which element is out of bounds.

124-125

Not defined.

126LFORMx form length parameter n error

The number of lines exceeds 66 (for 6 lpi) or 88 (for 8 lpi) lines when using the LFORMx command.

127Not defined.

128FORM/LOGO name is not a legal file name

The file name exceeds the fifteen-character limitation, or an invalid character was used in the file name. Refer to IGP Command Standards in the “Commands” chapter.

129Not defined.

Incremental Fields Errors

130Not defined.

131Incremental STEPMASK parameter error

A semicolon is missing after the STEPMASK data.

132Incremental REPEAT/RESET parameter error

An illegal RPT or RST parameter value was found in the incremental command. The value must range from 1 through 65,535.

133Incremental STEPMASK/STARTDATA length error

The dynamic stepmask exceeded created field length or start data exceeded stepmask.

134Incremental EXECUTE command error

An illegal IRST or ICNT parameter value was found in the Execute command. The value must range from 1 through 65,535.

135Not defined.

136Incremental STEPMASK/STARTDATA mismatched The STARTDATA value must be A-Z or 0-9, when the STEPMASK value is a value from 0-9.

Multinational Character Set Errors

150ISET character selection parameter n error

An ISET character set selection parameter value was expected. Error was caused possibly by an invalid numeric value or an alpha character. See Chapter 5.

151USET decimal input error in input parameter

The USET command was expecting a decimal parameter and either received none or received an alpha character.

152USET character set n parameter error

A USET character set selection parameter value between 1 and 8

274

Page 274
Image 274
Printronix LQH-HWTM manual Incremental Fields Errors, Multinational Character Set Errors