Logo Call

SR

Defines the starting row of the logo. The SR (and

 

SC) parameter specifies the location for the logo

 

based on the upper left corner of the grid in which

 

the logo was defined. Enter a value ranging from

 

row 1 through one less than the length of the form.

 

Character row or dot row is specified based on the

 

Scale command (page 83), or use the CP.DP

 

format (page 26).

SC

Defines the starting column of the logo. The SC

 

(and SR) parameter specifies the location for the

 

logo based on the upper left corner of the grid in

 

which the logo was defined. Enter a value ranging

 

from column 1 through one less than the width of

 

the form. Character column or dot column is

 

specified based on the Scale command (page 83),

 

or use the CP.DP format (page 26).

logoname

Identifies a previously defined logo by name for use

 

on the form. Enter the logo name exactly as used to

 

define and store the logo.

DISK

Optional parameter to retrieve logo from the flash

 

memory. Enter DISK.

STOP

Stop indicates the end of the LOGO command;

 

enter STOP, and the IGP will wait for a new

 

command. If not entered, the IGP expects another

 

set of Logo Call command parameters.

Example The following sample program specifies three logo calls placing the same logo at three different locations. (The logo was previously defined and stored.) The starting row and column specify the upper left corner of the grid in which the logo was defined. To illustrate positioning, the starting row and column are indicated on the example but do not necessarily reflect actual location on the page.

LOGO 56;35;HAND 56;50;HAND 56;65;HAND

STOP

SR 56

SC 35

SC 50

SC 65

Note When the logo to be executed is not found in memory, the “LOGO NOT FOUND” error is printed.