Chapter 6 IGP/PGL Emulation Error Codes

Horizontal Line Errors

01HORiZontal line starting row SR out of bounds

The row specified by the second parameter in the horizontal line command places the horizontal line outside the boundaries of the form.

02HORiZontal line starting column SC out of bounds

The left (starting) column of the horizontal line specified by the third parameter in the horizontal line command places the horizontal line outside the boundaries of the form.

03HORiZontal line ending column EC out of bounds

The right (ending) column of the horizontal line specified by the fourth parameter in the horizontal line command places the horizontal line outside the boundaries of the form.

04HORiZontal line format or delimiter error

Some type of format or delimiter error was detected in the parameters of the horizontal line command. This error is usually caused by one or more of the following:

a.A missing semicolon;

b.A colon in place of a semicolon;

c.Too many or too few parameters in the command string;

d.Alpha characters instead of numeric characters in the parameters.

05Insufficient memory to store the HORiZontal line

No more room in the IGP memory exists for another horizontal line. The rest of the horizontal line commands are flushed until the Stop command is found. Processing will then continue normally. To create space in the IGP memory, delete forms with horizontal line elements that are no longer required.

06HORiZontal line starting column SC > ending column EC The left (starting) column parameter of the horizontal line command is greater than or equal to the right (ending) column parameter.

07HORiZontal line thickness LT error

The thickness of the horizontal line specified by the first parameter in the horizontal line command is incorrect. This error is usually caused by specifying a thickness of zero.