Proxima ASA 7910, 7911 manual Set Network Subchannel, Set Baud Rate

Models: 7911 7910

1 127
Download 127 pages 54.08 Kb
Page 84
Image 84
Set Network Subchannel

Message Format:

 

BYTE

command (ASCII ‘C’, 43H)

BYTE

seqno

BYTE

Radio Channel (1 to 15)

Set Network Subchannel

Purpose: To set the subchannel of the Serial Adapter’s network protocol.

Response Expected from Serial Adapter: “Subchannel Confirma- tion”

Message Format:

 

BYTE

command (ASCII ‘S’, 53H)

BYTE

seqno

BYTE

subchannel (1 to 15)

Set Baud Rate

Purpose: To set the baud rate of the Serial Adapter serial line. When the command is received, the Serial Adapter generates the Baud Rate Confirmation message. After that, it then switches to the new baud rate.

Response Expected from Serial Adapter: “Baud Rate Confirma- tion”

Message Format:

 

BYTE

command (ASCII ‘B’, 42H)

BYTE

seqno

BYTE

baudrate (HEX 02 through 0A)

78

Page 84
Image 84