Proxima ASA 7911 Baud Rate Confirmation, Station Search Reply, RangeLAN2 Parameter Confirmation

Models: 7911 7910

1 127
Download 127 pages 54.08 Kb
Page 91
Image 91
Baud Rate Confirmation

Message Format:

 

BYTE

response (ASCII ‘s’, 73H)

BYTE

seqno (from original command)

BYTE

subchannel (1 to 15, from original com

 

mand)

Baud Rate Confirmation

Purpose: This message is sent after a Set Baud Rate command is received by the Serial Adapter. Note that this message is sent at the old baud rate. The Serial Adapter switches to the new baud rate immediately after this response is sent.

Message Format:

 

BYTE

response (ASCII ‘b’, 62H)

BYTE

seqno (from original command)

BYTE

baud rate (02H to 0AH, from original

 

command)

Station Search Reply

BYTE

response (ASCII ‘a’, 61H)

4 BYTES

Serial number (IP address) of responding

 

station

RangeLAN2 Parameter Confirmation

BYTE

response (ASCII ‘o’, 6FH)

BYTE

seqno

BYTE

Function number

BYTE

status

 

0= success

 

1= error

85

Page 91
Image 91
Proxima ASA 7911, 7910 manual Baud Rate Confirmation, Station Search Reply, RangeLAN2 Parameter Confirmation