Message Format: |
|
BYTE | response (ASCII ‘s’, 73H) |
BYTE | seqno (from original command) |
BYTE | subchannel (1 to 15, from original com |
| mand) |
Baud Rate Confirmation
Purpose: This message is sent after a Set Baud Rate command is received by the Serial Adapter. Note that this message is sent at the old baud rate. The Serial Adapter switches to the new baud rate immediately after this response is sent.
Message Format: |
|
BYTE | response (ASCII ‘b’, 62H) |
BYTE | seqno (from original command) |
BYTE | baud rate (02H to 0AH, from original |
| command) |
Station Search Reply
BYTE | response (ASCII ‘a’, 61H) |
4 BYTES | Serial number (IP address) of responding |
| station |
RangeLAN2 Parameter Confirmation
BYTE | response (ASCII ‘o’, 6FH) |
BYTE | seqno |
BYTE | Function number |
BYTE | status |
| 0= success |
| 1= error |
85