Chapter 5: Configuration
Translations Tab
Scan Indicator
When this parameter is enabled, the laser warning logo appears on the display whenever the scanner is activated.
Scan Result Time (sec)
The value assigned to the ‘Scan Result Time (sec)’ parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of ‘0’ (zero) disables the parameter. When you choose this option, a dialog box appears where you can enter a value.
Note: | To remove the scan result from the screen before the “Result Time” has |
| expired, point the scanner away from the bar code and press the trigger. |
Good Scan Beep And Bad Scan Beep
These parameters determine whether or not the
Soft Scan Timeout
This parameter is used by the SDK ‘Scan’ function
Scan Log File
If this parameter is enabled, the input bar code and the modified/translated output bar code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if this parameter is en- abled, there is a slight performance effect when performing multiple scans because the log file is written to persistent storage.
5.17.3Translations Tab
The Translations tab allows you to define up to 10 cases, each consisting of up to 10 rules in sequential order. Only one case will be applied to a bar code and a case will only be applied if all rules specified in the case are
Psion Teklogix 8515 | 111 |