Manuals
/
Q-Logic
/
Computer Equipment
/
Switch
Q-Logic
59021-05 B
manual
SANbox2-16 Fibre Channel Switch Installation Guide
Models:
59021-05 B
1
1
178
178
Download
178 pages
6.65 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Specs
Install
Alarm
Fatal Error Blink Pattern
Admin Command
Dimension
Maintenance
Configure the Switch
Reset Command
Page 1
Image 1
D
S i m p l i f y
SANbox2-16
Fibre Channel Switch
Installation Guide
59021-05
B
Page i
Page 2
Page 1
Image 1
Page 2
Contents
SANbox2-16 Fibre Channel Switch Installation Guide
Document Revision History
SANbox2-16 Fibre Channel Switch Installation Guide
Table of Contents
Section Planning
Section Installation
Section
Diagnostics/Troubleshooting
Appendix a Specifications
Section Removal/Replacement
Appendix B Command Line Interface
Figures
Glossary Index
Tables
Intended Audience
Introduction
Related Materials
Sicherheitshinweise
Safety Notices
Federal Communications Commission FCC Class a Statement
Communications Statements
CE Statement
Bsmi Class a Statement
Vcci Class a Statement
Electrostatic Discharge Sensitivity Esds Precautions
Laser Safety Information
Pièces Accessibles
Accessible Parts
Zugängliche Teile
Availability
Technical Support
Training
Contact Information
Introduction Technical Support 59021-05 B
General Description
Maintenance Button
Power Switches
Chassis Controls and LEDs
Chassis LEDs
Over Temperature LED Amber
Fan Fail LED Amber
Heartbeat LED Amber
Input Power LED Green
Fibre Channel Ports
Port LEDs
Small Form-Factor Pluggable SFP Transceivers
Activity LED
Logged-In LED
Port Modes
Translated Loop Port
Fabric Ports
Expansion Port
Serial Port
Ethernet Port
Serial Port Pin Identification
Power Supplies
10. Fans
Fans
Switch Management
General Description Switch Management 59021-05 B
Devices
Planning
Domain ID, Principal Priority, and Domain ID Lock
Multiple Chassis Fabrics
Cascade Topology
Common Topologies
Mesh Topology
Mesh Topology
Multistage Topology
Multistage Topology
Distance
Performance
Latency
Bandwidth
Port-to-Port Transmission Combinations
Port-to-Port Latency
Device Access
Soft Zones
Access Control List Hard Zones
Fabric Management
Virtual Private Fabric Hard Zones
Fabric Security
Planning Fabric Security 59021-05 B
Site Requirements
Switch Power Requirements
Fabric Management Workstation
Management Workstation Requirements
Environmental Conditions
Installing a Switch
Mount the Switch
Installing Rack Mount Brackets
Install SFP Transceivers
Avertissement
Connect the Switch to AC Power
Warnung
Installation Installing a Switch
Ethernet and Serial Cable Connections
Connect the Management Workstation to the Switch
Serial Connection
Ethernet Connection
Enter the following command at the Solaris prompt
Install SANbox Manager
SANsurfer Management Suite Disk Windows Installation
Enter the following command
SANsurfer Management Suite Disk Linux Installation
Press the Enter key Enter the following command
SANsurfer Management Suite Disk Solaris Installation
SANbox2 Installation Disk Linux Installation
SANbox2 Installation Disk Windows Installation
SANbox2 Installation Disk Solaris Installation
Configure the Switch
Cable Devices to the Switch
Configure the Ports
Using SANbox Manager to Install Firmware
Install Firmware
To start an admin session, enter the following
Using the CLI to Install Firmware
Enter the following command to install the new firmware
Close the FTP session
Using FTP and the CLI to Install Firmware
Powering Down a Switch
Heartbeat LED Blink Patterns
Post Diagnostics
Normal all pass
Fatal Error Blink Pattern
Maintenance Mode Pattern
Configuration File System Error Blink Pattern
Internal Firmware Failure Blink Pattern
Enter the following account name and password userimages
Restore the configuration file
Logged-In LED Indications
Logging Error
EPort Isolation
Excessive Port Errors
Diagnostics/Troubleshooting Post Diagnostics
Chassis and Power Supply LEDs
Chassis Diagnostics
Input Power LED Is Extinguished
Chassis Over Temperature LED is Illuminated
Fan Fail LED is Illuminated
Power Supply Over Temperature LED is Illuminated
Output Power LED Is Extinguished
Recovering a Switch
Maintenance Image Unpack
Maintenance Exit
Maintenance Reset Password File
Maintenance Reset Network Config
Maintenance Copy Log Files
Maintenance Remove Switch Config
Removal/Replacement
SFP Transceivers
SFP Transceiver Installation
Power Supply Removal
Fan Removal
Fan Installation for Switch Model SB2A-16B
Removal/Replacement Fans 59021-05 B
Switch Specifications
Switch Maintainability
Switch Electrical
Switch Dimensions
Switch Regulatory Certifications
Switch Environmental
Depending on the switch model
Shortwave Laser SFP 1G/2G multi-mode
Longwave Laser SFP 1G/2G single-mode
Logging On to a Switch
Command Line Interface
Command syntax is as follows
Command Syntax
Command keyword keyword value
Table B-1. Commands Listed by Authority Level
Commands
Authority
Admin Command
Syntax
Keywords
Authority Admin Syntax alias
Alias Command
Remove alias members
Members alias
Rename aliasold aliasnew
Syntax config
Config Command
Keywords activate config
Edit config
Save config
Restore
Syntax date
Date Command
Keywords MMDDhhmmCCYY
Following is an example of the Fallback command
Fallback Command
Fallback
Currently active version
Keywords command
Help Command
Syntax help command keyword
Authority User
Authority User Syntax history
History Command
Authority Admin Syntax image cleanup
Image Command
Keywords cleanup
Unpack file
Authority Admin
Lip Command
Reinitializes the specified loop port
Syntax lip portnumber Keywords portnumber
Syntax passwd accountname Keywords accountname
Passwd Command
Authority User Syntax ping
Ping Command
Ipaddress
Keywords ipaddress
Following is an example of the Ps command
Ps Command
Syntax Examples
Displays current system process information
Closes the Telnet session
Quit Command
Syntax quit, exit, or logout
Config configname
Reset Command
Table B-3. Port Configuration Defaults
Table B-2. Switch Configuration Defaults
Table B-4. Alarm Threshold Configuration Defaults
Table B-5. Snmp Configuration Defaults
Table B-6. System Configuration Defaults
Syntax set
Set Command
Switch state
Setup option
Port option
Set config
Set Config Command
Table B-7. Set Config Port Parameters
Port portnumber
Use Arbff instead of idles on loop Fcal option
Table B-8. Set Config Switch Parameters
Threshold
Table B-9. Set Config Threshold Parameters
Arbff
Table B-10. Set Config Zoning Parameters
Following is an example of the Set Config Threshold command
Following is an example of the Set Config Switch command
Decimal value, 1-1000 sec DecodeErrorsMonitoringEnabled
Following is an example of the Set Config Zoning command
Set log
Set Log Command
Archive
Clear
Port portlist
Level level
Save
Stop
Start
Stops logging of events
Level keyword to Info at the same time
Set Port Command
Set setup
Set Setup Command
Table B-11. Snmp Configuration Settings
Snmp System
Rarp
Table B-12. System Configuration Settings
Values will follow
Trap1Severity See
Following is an example of the Set Setup System command
Alarm
Show Command
Keywords about
Broadcast
Ns option
Log option
Table B-13. Show Port Parameters
Perf option
LIPF7F7
Steering domainid
Post log
Support
Users
Topology
Version
Following is an example of the Show NS DomainID command
Following is an example of the Show NS local domain command
Following is an example of the Show Interface command
Picolight
Following is an example of the Show Port command
Following is an example of the Show Topology command
Following is an example of the Show Switch command
Following is an example of the Show Version command
Show config
Show Config Command
Following is an example of the Show Config Threshold command
Following is an example of the Show Config Switch command
Following is an example of the Show Config Zoning command
Keywords component
Show Log Command
Following is an example of the Show Log command
Following is an example of the Show Log Options command
Show Perf Command
Following is an example of the Show Perf Byte command
Show setup
Show Setup Command
Mfg
Following is an example of the Show Setup System command
Syntax shutdown
Shutdown Command
Syntax test
Test Command
Keywords port portnumber testtype
Status
Test x internal
Command Line Interface Test Command
Examples The following is an example of the Uptime command
Uptime Command
Authority User Syntax uptime
Displays all user accounts that exist on the switch
User Command
Keywords accounts
Add
Following is an example of the User Delete command
Following is an example of the User Add command
Following is an example of the User List command
Following is an example of the Whoami command
Whoami Command
Whoami
Syntax zone
Zone Command
Remove zone members
Members zone
Rename zoneold zonenew
Type zone zonetype
Following is an example of the Zone Members command
Following is an example of the Zone Zonesets command
Syntax zoneset
Zoneset Command
Delete zoneset
Following is an example of the Zoneset List command
Remove zoneset zonelist
Rename zonesetold zonesetnew
Following is an example of the Zoneset Zones command
Edit
Zoning Command
Opens a Zoning Edit session
History
Limits
Following is an example of the Zoning List command
Command Line Interface Zoning Command
Command Line Interface Zoning Command 59021-05 B
Class 2 Service
BootP
Class 3 Service
Fabric Management Switch
MSEnable
Input Power LED
Output Power LED
Over Temperature LED
SANbox Manager
Private Loop
Small Form Factor
Small Form-Factor Pluggable
Page
Numerics
Index
Index-2 59021-05 B
59021-05 B Index-3
Index-4 59021-05 B
59021-05 B Index-5
Index-6 59021-05 B
Top
Page
Image
Contents