Q

2 – General Description Power Supplies

The serial port connector requires a null-modem F/F DB9 cable. The pins on the switch RS-232 connector are shown in Figure 2-8and identified in Table 2-1. Refer to ”Connect the Management Workstation to the Switch” on page 4-8for information about connecting the management workstation through the serial port.

 

Table 2-1. Serial Port Pin Identification

 

 

 

Pin Number

 

Description

 

 

 

1

 

Carrier Detect (DCD)

2

 

Receive Data (RxD)

3

 

Transmit Data (TxD)

4

 

Data Terminal Ready (DTR)

5

 

Signal Ground (GND)

6

 

Data Set Ready (DSR)

7

 

Request to Send (RTS)

8

 

Clear to Send (CTS)

9

 

Ring Indicator (RI)

 

 

 

2.5

Power Supplies

The power supplies convert standard 110 or 230 VAC to DC voltages for the various switch circuits. Each power supply has an AC power receptacle, an On/Off switch, and two status LEDs as shown in Figure 2-9. After connecting a power supply to an AC voltage source and placing the power switch in the On position, the power supply is energized and DC voltage is delivered to the switch logic circuitry. Refer to Section 6 Removal/Replacement for information about replacing a power supply.

Over Temperature LED

Output Power LED

(Amber)

(Green)

AC Power

On/Off Switch

Receptacle

 

Figure 2-9. Power Supply Components

59021-05 B

2-9

Page 27
Image 27