Table B-12. System Configuration Settings

Q

B – Command Line Interface Set Setup Command

 

Table B-11. SNMP Configuration Settings

 

 

 

Entry

 

Description

 

 

 

TrapCommunity

 

Trap community password that authorizes an SNMP agent

 

 

to receive traps. This is a write-only field. The value on the

 

 

switch and the SNMP management server must be the

 

 

same. The default is “public”.

AuthFailureTrap

 

Enables (True) or disables (False) the generation of traps in

 

 

response to trap authentication failures. The default is

 

 

False.

ProxyEnabled

 

Enables (True) or disables (False) SNMP communication

 

 

with other switches in the fabric. The default is True.

 

 

 

system

Prompts you in a line-by-line fashion to change system configuration settings. Table B-12describes the system configuration fields. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.

Table B-12. System Configuration Settings

Entry

Description

 

 

Eth0NetworkDiscovery

Boot Method (1 - Static, 2 - Bootp, 3 - DHCP, 4 -

 

RARP)

Eth0NetworkAddress

Internet Protocol (IP) address for the Ethernet port.

Eth0NetworkMask

Subnet mask address for the Ethernet port.

Eth0GatewayAddress

IP address gateway.

AdminTimeout

Specifies the amount of time in minutes the switch

 

waits before terminating an idle Admin session.

 

Zero (0) disables the time out threshold. The

 

default is 30, the maximum is 1440.

TempMonitoringWarning

Warning temperature threshold in °C above which

 

a warning condition alarm is generated. The

 

default is 65 °C.

TempMonitoringFailure

Failure temperature threshold in °C above which a

 

failure condition alarm is generated. The default is

 

70 °C.

TempFailurePortShutdown

Enables (True) or disables (False) the switch’s

 

ability to place all ports offline when the internal

 

temperature exceeds the failure threshold. The

 

default is False.

 

 