Q
B – Command Line Interface Set Setup Command
| Table | |
|
|
|
Entry |
| Description |
|
|
|
TrapCommunity |
| Trap community password that authorizes an SNMP agent |
|
| to receive traps. This is a |
|
| switch and the SNMP management server must be the |
|
| same. The default is “public”. |
AuthFailureTrap |
| Enables (True) or disables (False) the generation of traps in |
|
| response to trap authentication failures. The default is |
|
| False. |
ProxyEnabled |
| Enables (True) or disables (False) SNMP communication |
|
| with other switches in the fabric. The default is True. |
|
|
|
system
Prompts you in a
Table B-12. System Configuration Settings
Entry | Description |
|
|
Eth0NetworkDiscovery | Boot Method (1 - Static, 2 - Bootp, 3 - DHCP, 4 - |
| RARP) |
Eth0NetworkAddress | Internet Protocol (IP) address for the Ethernet port. |
Eth0NetworkMask | Subnet mask address for the Ethernet port. |
Eth0GatewayAddress | IP address gateway. |
AdminTimeout | Specifies the amount of time in minutes the switch |
| waits before terminating an idle Admin session. |
| Zero (0) disables the time out threshold. The |
| default is 30, the maximum is 1440. |
TempMonitoringWarning | Warning temperature threshold in °C above which |
| a warning condition alarm is generated. The |
| default is 65 °C. |
TempMonitoringFailure | Failure temperature threshold in °C above which a |
| failure condition alarm is generated. The default is |
| 70 °C. |
TempFailurePortShutdown | Enables (True) or disables (False) the switch’s |
| ability to place all ports offline when the internal |
| temperature exceeds the failure threshold. The |
| default is False. |
|
|